Buzzer settings, Start/end program menu – Opticon OPT-6125 User Manual

Page 57

Advertising
background image

Manual No. 25-ULGPMU01-01 Series OPT Handheld
CCD Scanner

Page 57

Read Mode Settings

ZZ

Start/End

Program

Menu

-[[-

S0

Single

read

-T1-

S1

Multiple

read

-T2- %

S2

Continuous

read

-T3-

XA

Add-on

wait mode

disabled

-YB-

XB

Add-on

wait mode

0.25 sec.

-TC-

XC

Add-on

wait mode

0.50 sec.

-YD- %

XD

Add-on

wait mode

0.70 sec.

-YE-

Single Read - When a bar code has been decoded, the reader will be turned OFF. The reader must be triggered again
to read another label. This option and "Disable trigger" cannot be programmed at the same time.
Multiple Read - When a bar code has been decoded, the reader will stay ON for a time as set by "read time
settings" or indefinitely if the trigger switch has been disabled. The same label can only be decoded again after the
label has not been detected for a number of scans.
Continuous Read - The reader will produce as much data as it can decode regardless whether it is the same or not.
This mode is mainly used for demonstration and diagnosis.
Add-on Wait Mode - Used if UPC/EAN with add-on is enabled. The reader searches within the selected time for a
valid add-on code. If a valid add-on code is found, the reader transmits the data immediately. If nothing is found
behind the code, the scanner will transmit the data without add-on. If something is found behind the code, the reader
ignored the code in case it is not a valid add-on.