SUUNTO D4 User Manual

Page 84

Advertising
background image

Tissue calculation model:

Suunto Deep Stop RGBM algorithm (developed by Suunto and Bruce R. Wienke,
BSc, MSc, PhD)

9 tissue compartments

Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240 and 480 minutes
(on gassing). The off gassing halftimes are slowed down

Reduced gradient (variable) "M" values based on diving habit and dive violations.
The "M" values are tracked up to 100 hours after a dive

The EAN and oxygen exposure calculations are based on recommendations by
R.W. Hamilton, PhD and currently accepted exposure time limit tables and principles

Battery:

One 3 V lithium battery: CR 2450

Battery storage time (shelf life): Up to three years

Replacement: Every two years, or more often depending on dive activity

Life expectancy at 20°C/68°F:

0 dives/y –> 2 years

100 dives/year –>1,5 years

300 dives/year –>1 year

The following conditions have an effect on the expected battery lifetime:

The length of the dives

The conditions in which the unit is operated and stored (e.g. temperature/cold
conditions). Below 10°C/50°F the expected battery lifetime is about 50-75% of that
at 20°C/68°F

The use of the backlight and audible alarms

85

Advertising