For your safety, Items supplied, Description – Oki BTX-208 User Manual

Page 2: Installation, Operation and maintenance, Maintenance

Advertising
background image

For Your Safety
For safe and successful operation of the unit, read these instructions completely. If the instructions are not observed,
the manufacturer can assume no responsibility. Retain this manual for future reference.

Always disconnect the power supply before servicing the unit.

Do not operate the Unit without filter inserts. Contaminants in the extracted air will damage the blower. Use only
original equipment filters.

The BVX-208 is designed for the removal of solder fumes. Use filter unit only for this purpose. Consult your “safety
department” when using the unit on flammable gases. This unit is not explosion safe and can only be used for the
extraction of vapors, which have concentration levels well below the lower explosive limits.

This system is equipped with automatic reset overload protection, which may cause the unit to restart automatically.

While under warranty, the unit may be repaired only by an authorized Metcal Service Representative.

Items Supplied
1 Filter Unit with filters installed
1 32mm hose adapter

1

2

5

3

4

1 air inlet cover installed on second air inlet port
1 Power Cord
1 Operating Manual

Description
(1) ON/OFF switch
(2) Power Output
(3) 32mm hose adapter
(4) air inlet cover with bypass valve
(5) latch (front and back)

2

5

1

3

4

Installation

• Place filter unit (1) at a location which minimizes length of ducting

• Screw supplied hose adapter into open air inlet port (2)

• Install ducting (3) as per duct installation instructions

• Install iron adapter kits (4)

• Connect filter unit to power supply (5)


Operation and Maintenance

• Turn unit ON.

Air inlet cover

with bypass

valve

• Check if the motor pump indicates an acoustical “fluttering” effect. If yes,

open air by-pass valve on air inlet cover until “fluttering” sound
disappears. Do not open too much as this will reduce the airflow
performance. The “fluttering” does not cause any damage to the system.



Maintenance
The airflow of the filter unit decreases during operation due to several
re ons:

as

solder iron

Saturation of pre and main-filter inside filter unit

2

1

• Clogging of vacuum tubes and hoses attached to



Tip Extraction Accessories:
Clean stainless steel vacuum tubes (1) periodically and frequently.
Cleaning brushes are supplied with the iron adapter kits. Inspect vacuum

oses (2) visually and clean if needed.

h

2