The instrument is a portable digital thermometer that
measures external thermocouples of type K, J, R, S, T, E,
N. The thermocouples types comply with the N.I.S.T. –
ITS 90 standard reference temperature/voltage tables.
The thermometer features a dual thermocouple input, an
adjustable T/C offset and an USB interface for uploading
data to a PC using optional software and cable.

SAFETY INFORMATION

WARNING

To avoid electrical shock, do not use this instrument

when working voltages at the measurement surface

over 24V AC or DC.

WARNING

To avoid damage or burns, do not make temperature

measurement in microwave ovens.

CAUTION

Repeated sharp flexing can break the thermocouple

leads. To prolong lead life, avoid sharp bends in the

leads, especially near the connector.

SPECIFICATIONS

ELECTRICAL

Temperature Scale: Celsius or Fahrenheit user-selectable
Measurement Range:
K-TYPE (0.1°) -200°C to 1372°C (-328°F to 2501°F)
J-TYPE (0.1°) -210°C to 1200°C (-346°F to 2192°F)
T-TYPE (0.1°) -200°C to 400°C (-328°F to 752°F)
E-TYPE (0.1°) -210°C to 1000°C (-346°F to 1832°F)
R-TYPE (1°)

0°C to 1767°C (32°F to 3212°F)

S-TYPE (1°)

0°C to 1767°C ( 32°F to 3212°F)

N-TYPE (0.1°) -50°C to 1300°C ( -58°F to 2372°F)

*Based on the ITS-90 temperature standard.

According to temperature standard ITS-90.

Accuracy:
K/J/T/E-TYPE

±(0.05% rdg + 0.3°C) on -50°C to 1372°C
±(0.05% rdg + 0.7°C) on -50°C to -210°C
±(0.05% rdg + 0.6°F) on -58°F to 2501°F
±(0.05% rdg + 1.4°F) on -58°F to -346°F

N-TYPE

±(0.05% rdg + 0.8°C) on -50°C to 0°C
±(0.05% rdg + 0.4°C) on 0°C to 1300°C
±(0.05% rdg + 1.6°F) on -58°F to 32°F
±(0.05% rdg + 0.8°F) on 32°F to 2372°F

R/S-TYPE

±(0.05% rdg + 2°C) on 0°C to 1767°C
±(0.05% rdg + 4°F) on 32°F to 3212°F

Temperature Coefficient:
0.1 times the applicable accuracy specification per °C
from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and
82°F to122°F).

Input Protection:
24V dc or 24V ac rms maximum input voltage on any
combination of input pins.

Reading Rate: 2.5 time per second.

ENVIRONMENTAL

Ambient Operating Ranges:
0°C to 50°C (32°F to 122°F) <80% R.H.
Storage Temperature:
-20°C to 60°C (-4°F to 140°F) <70% R.H.

GENERAL

Display:
There are three display areas on the HH806 series LCD
(liquid crystal display). The Main and Second displays
are 4 ½ digits with a maximum reading of 19999. These
are used for displaying the value of T1 or T2. The Third
display is for the date, time, or the differential value of
T1 to T2.

Overload: “----.-” or “OL” is display.

Battery: 1.5V x 4 PCS (SIZE AAA) UM-4 R03.

Battery Life: 120 hours typical with carbon zinc battery.

Dimensions: 160mm(H) x 83mm(W) x 38mm(D).

Weight: Approx. 365g including batteries.
Supplied Thermocouple:
1 meter (40”) type K insulated beaded wire thermocouple
Maximum insulation temperature is 482°C (900°F).
Thermocouple accuracy is ±1.1°C or 0.4% of reading
(whichever is greater) from 0°C to 1250°C.
Wire Communication Protocol:
2400 baud rate. (HH806U)
19200 baud rate. (HH806A)

External Connections:
1. USB Port
2. DC power JACK(12V)

HH806U/HH806AU

MULTILOGGER THERMOMETER

M4502/0711

Shop online at: omega.com e- mail: [email protected]

For latest product manuals: omegamanual.info

INSTRUCTION

SHEET

MADE IN TAIWAN

OMEGAnet

On-Line Service

omega.com

Internet e-mail

[email protected]

Servicing North America:

U.S.A:

One Omega Drive, Box 4047
Stamford, CT 06907-0047

ISO 9001

Tel: (203) 359-1660

FAX: (203) 359-7700

Certified

e-mail: [email protected]

Canada:

976 Bergar
Laval (Quebec) H7L 5A1, Canada
Tel: (514) 856-6928

FAX: (514) 856-6886

e-mail: [email protected]

For immediate technical or application assistance:

U.S.A

Sales Service: 1-800-826-6342/1-800-TC-OMEGA

®

and

Customer Service: 1-800-622-2378/1-800-622-BEST

®

Canada:

Mexico:

En Espan ol: (001) 203-359-7803
e-mail: [email protected]
FAX: (001) 203-359-7807 [email protected]

Servicing Europe:

Benelux:

Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: +31 (0)20 3472121

FAX: +31 (0)20 6434643

Toll Free in Benelux: 0800 0993344
e-mail: [email protected]

Czech

Frystatska 184, 733 01 Karviná, Czech Republic

Republic: Tel: +420 (0)59 6311899

FAX: +420 (0)59 6311114

Toll Free: 0800-1-66342

e-mail: [email protected]

France:

11, rue Jacques Cartier, 78280 Guyancourt, France
Tel: +33 (0)1 61 37 2900

FAX: +33 (0)1 30 57 5427

Toll Free in France: 0800 466 342
e-mail: [email protected]

Germany/ Daimlerstrasse 26, D-75392 Deckenpfronn, Germany

Austria:

Tel: + 49 (0)7056 9398-0

FAX: +49 (0)7056 9398-29

Toll Free in Germany: 0800 639 7678
e-mail: [email protected]

United

One Omega Drive, River Bend Technology Centre

Kingdom: Northbank, Irlam, Manchester

ISO 9002

M44 5BD United Kingdom

Certified

Tel: +44 (0)161 777 6611

FAX: +44 (0)161 777 6622

Toll Free in United Kingdom: 0800-488-488
e-mail: [email protected]

It is the policy of OMEGA Engineering, Inc. to comply with all

worldwide safety and EMC/EMI regulations that apply. OMEGA

is constantly pursuing certification of its products to the

European New Approach Directives. OMEGA will add the CE

mark to every appropriate device upon certification.

The information contained in this document is believed to be

correct, but OMEGA accepts no liability for any errors it

contains, and reserves the right to alter specifications without

notice.

These products are not designed for use in, and

should not be used for, human applications.