12

Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide • April 2010

3. Observe the port LEDs status for the power-on self test (POST) results as

shown in

TABLE 2-2

.

TABLE 2-2

summarizes port LED indicator combinations. Refer to

FIGURE 2-4

to

determine the location of the LEDs. Each port has a corresponding set of LEDs
that provide a visual indication of the operating state.

TABLE 2-2

Port LED Indicator Status Definitions

Green LED

Yellow LED

State

On

1 fast blink

1-Gb link rate - Normal operating state, link up

On

2 fast blinks

2-Gb link rate - Normal operating state, link up

On

3 fast blinks

4-Gb link rate - Normal operating state, link up

Off

Off

One of the following:
• Wake-up failure (failed board)
• Server not powered on
• Server not providing power to the board

Off

On

POST failure (failed board)

Off

Slow blink

Wake-up failure monitor

Off

Fast blink

Failure in POST

Off

Flashing

POST processing in progress

On

Off

Failure while functioning

On

On

Failure while functioning

Slow blink

Off

Normal - link down

Slow blink

On

Not defined

Slow blink

Slow blink

Off-line for download

Slow blink

Fast blink

Restricted off-line mode (waiting for restart)

Slow blink

Flashing

Restricted off-line mode, test active