Wood insert specifications, Wood insert clearances, Technical data performance – Quadra-Fire 5100I User Manual

Page 7: Bc f e

Advertising
background image

WOOD insert specificatiOns

technical Data

performance

Width

Fireplace

Opening

(inches)

Width

Back of In-

sert (inches)

Height

(inches)

Depth

Into

Fireplace

(inches)

Extension

Onto

Hearth

(Ashlip)

(inches)

Weight

(lbs.)

Peak

btu/hr

(on High)

Max. Burn

Time

Firebox

Capacity

(cu.ft.)

Max. Log

Length

Emissions

(g/hr)

Efficiency

2700i

27-5/16

18-1/2

22-1/16

17-1/16

6-15/16

278

45,000

7.7-10.4

1.6

18”/

16” Ideal

4.14

Up to

74%

3100i

27-7/16

22-7/16

21-1/2

14-1/8

12-3/16

333

45,500

11.4-15.3

2.0

18”/

16” Ideal

1.26

Up to

78%

4100i

30

24

21-5/8

16-1/4

10-7/8

345

65,600

12.2-16.4

2.47

18”/

16” Ideal

3.1

Up to

76%

5100i

34-3/16

25-5/8

22-1/4

17-5/8

10-1/2

520

71,200

14.2-19.1

3.0

21"

1.98

Up to

75.5%

WOOD insert clearances

Model

surround

sizes

Wood inserts clearance

see diagram below

factory Build

Zero clearance

(Us only)

thermal

protection

(Us & canada)

2700i

Standard

30-1/2"h x 44-5/8"w

Large

34-1/2"h x 50-1/2"w

Model

A

B

C

D

E

F

2700i

14"

21"

14"

9"

16"

9"

Inches

Minimum width of cavity opening

28

Minimum height

18-7/8

Minimum depth from front to rear

17

1/4" minimum thickness

"k" value= 0.84 or equivalent

material

3100i

Standard

30-1/2"h x 44-3/4"w

Large

34-1/2"h x 50-1/2"w

Model

A

B

C

D

E

F

Floor height

0" - 8"

Floor height

greater than 8"

3100i

16" 33" 30"

6"

18"

16"

8"

With 8" mantel deflector 16" 17"

16"

6"

18"

16"

8"

With mantel shield*

16" 24" 22"

6"

18"

16"

8"

With mantel shield & 8"

mantel deflector

16" 15"

12"

6"

18"

16"

8"

* The mantel shield must be a non-combustible material located a minimum
of 1" from mantel's under side extending to the full width of the mantel.

Inches

Minimum width of cavity opening

32

Minimum height

23

Minimum depth from front to rear

16

Floor 0"- 8" below insert:

1" minimum thickness,
Floor greater than 8" below

insert: 1/2" minimum

thickness
"k" value= 0.84 or equivalent

material

4100i

Cast Iron Trim

Standard

30-1/2"h x 44-3/4"w

Large

34"h x 48"w

Basic Panel

with Trim

30-1/2"h x 44-5/8"w

Model

A

B

C

D

E

F

4100i

15"

26"

20"

6"

16"

8"

Inches

Minimum width of cavity opening

30

Minimum height

21

Minimum depth from front to rear

16-1/4

1/2" minimum thickness

"k" value= 0.84 or equivalent

material

5100i

Standard

31-1/2"h x 47"w

Large

34"h x 51"w

Model

A

B

C

D

E

F

USA

Canada

5100i

12" 40" 35"

7"

16”

18”

8"

With 8" Mantel Deflector

12" 27" 16"

7"

16”

18”

8"

Inches

Minimum width of cavity opening

36

Minimum height

24

Minimum depth from front to rear

19

1/2" minimum thickness

"k" value= 0.84 or equivalent

material

Note: Minimum clearances shown.

Refer to the Owner/Installation Manual for complete clearance requirements and specifications.

Hearth Extension

B

C

F

E

Insert

SideW

all

Maximum Mantel Depth - 10" (254mm)

Fascia or Trim

Mantel

A

D

7

Advertising