Warning, Cb 1200 pellet stove, E. masonry f. alternate masonry – Quadra-Fire CB1200M-MBK User Manual

Page 16

Advertising
background image

Page 16

7014-179D

December 16, 2011

R

CB 1200 Pellet Stove

Fire Hazard
Inspection of Chimney:
• Masonry chimney must be in good condition.
• Meets minimum standard of NFPA 211
• Factory-built chimney must be minimum6 in. (152mm)

UL103 HT.

WARNING

E. Masonry

F. Alternate Masonry

Non-Combustible Hearth Pad

Airtight

Clean-out Door

Cleanout Cover

Sheathing

3 in. (76mm) Minimum

1 in. (25mm) Clearance

Flashing

Fireclay Flue

Liner with Airspace

Concrete Cap

1 in. (25mm) Clearance

with Firestop

6 in. (152mm)

Minimum

Non-Combustible Hearth Pad

Sheathing

2 in. (51mm) Minimum

1 in. (25mm)

Clearance

Flashing

Fireclay Flue Liner

with Airspace

Concrete Cap

6 in. (152mm)

Minimum

Airtight Clean-out Door

1 in. (25mm) Clearance

with Firestop

Figure 16.1