Connections – QSC Audio S series User Manual

Page 17

Advertising
background image

17

REDUNDANT CONFIGURATION

(hardware setup)

To slave one RAVE unit to another, connect a male-to-male

BNC jumper cable from the sync output of the master unit to

the slave input of the redundant unit. Select the same bundle

assignment(s) on the slave unit as are selected on the mas-

ter unit.

Bundle assignments and additional parameters available for

redundant operation may be configured through MI variables

via SNMP. Redundancy for network links, hardware and

routing is also possible. Refer to the Peak Audio and QSC

Audio websites regarding additional methods for redundant

and fail-safe operation on switched Ethernet LANs.

RS-232 PORT

The RS-232 port is an auxiliary interface which serves two

primary functions. It provides a serial method for upgrading

the CobraNet program code and it provides a means to bridge

serial data onto Ethernet. The serial bridge allows the user

to transmit serial data over the network, from one RAVE unit

to another. This is a handy feature for remotely controlling

and/or programming accessories and processors that require

an RS-232 serial interface. The serial data format is opti-

mized for RAVE at 19,200 baud, 9 bits (or 8 bits w/ parity), 1

stop bit. Note that no parity or data validity detection is done

within RAVE. The unit simply bridges the serial data onto

the network.

Incoming serial data is buffered and broadcast over the net-

work. All attached stations receive these broadcasts and

transmit the data simultaneously out their respective serial

ports. When the RS-232 electrical connection is in use, the

serial port operates in a half duplex mode. Port parameters

(including unicast transmission) may be configured via the

management interface, using SNMP.

For the DB-9 pinout information, see the Appendix.

Rear panel coax cable and Ethernet connections

Configuration example for redundant audio transmission

Note that audio connections must be present at both devices. This may be accomplished through
the use of “Y” connections or by channel duplication from a console or other source device.

Configuration example for redundant audio reception

Note that destination devices will need to be connected to audio sources from both RAVEs.
Although RAVE provides a means to do this directly, a splitter box, duplicate console inputs or
redundant amplifiers may also be used.

Connections: