QVS Interface Converter IC-485S User Manual

Page 5

Advertising
background image

IC-485S/IC-485SI

INSTALLATION

2-2 SWITCH FUNCTION DESCRIPTION

Refer to the location of the SW1 and SW2, please see
Figure 1- 1.

IC-485S:

IC-485SI:

SW 1: Device Mode Selection

Position 1: DCE means the IC-485 is set at DCE

mode and it must be connected to a DTE
device.

Position 2: DTE means the IC-485 is set at DTE

mode and it must be connected to a DCE
device.

Position 3: Monitor means the IC-485S is set at

monitor mode and it is used to monitor

User’s Manual

User’s Manual

INSTALLATION

IC-485S/IC-485SI

the RS-485 line signals (for IC-485S

only).

SW2: Transmitting and Receiving mode selection

Position 1: (TxON, RxON) means the IC-485 is

always in transmitting mode and in re-

ceiving mode.(using in Point-to-Point
mode)

Position 2: (TxRTS, RxRTS) means the K-485 is in

transmitting mode while RTS signal is at

high level and it is in receiving mode
while RTS signal is at low level.(using

in Multidrop mode)

Position 3: (TxRTS, RxON) means the IC-485 is

always in receiving mode and it is in

transmitting mode only while RTS sig-
nal is at high level.(using in Multidrop
mode to monitor the RS-485 line signals)

Note: DTE means Data Terminal Equipment.

DCE means Data Communication

Equipment.

More detailed information, please refer
to the Appendix.

5