Installation, Warning, 2100 millennium wood stove (acc) – Quadra-Fire 2100 Millennium Wood 21M-ACC User Manual

Page 11: A. hearth protection requirements, Usa canada

Advertising
background image

May 5, 2011

7039-131H

Page 11

2100 Millennium Wood Stove (ACC)

R

A. Hearth Protection Requirements

FLOOR PROTECTION: Floor protector must be non-com-

bustible material, extending beneath heater and to the front,

sides and rear as indicated. The floor must be non-com-

bustible or otherwise adequately protected from radiant heat

given off by the unit and from sparks and falling embers. A

layer of thin brick or ceramic tile over a combustible floor is

not sufficient.
In US installations, it is necessary to install a floor protector

of a minimum of 3/8 inch (9.5mm) thick metal clad millboard

or equivalent a minimum of 16 inches (406mm) in front of

glass and 8 inches (203mm) to both sides of the fuel loading

door. Open the door and measure 8 inches (203mm) from

the side edge of the opening in the face of the appliance.

*

See exception.

16" from glass

8 in.

USA

Fuel loading door

5-3/4 in. 2-1/4 in."

29-5/8 in.

minimum

39 in.

minimum

29

-5/

8 i

n.

25

-3/

8 i

n.

32-7/8 in.

39

in.

3 in.

13

op

tio

na

l

co

ve

rag

e

50-3/4 in.

Must extend 2 in. (51mm) beyond

each side of pipe (shaded area)

203mm (8 in.)

203mm

(8 in.)

203mm

(8 in.)

457mm (18 in.)

1244mm

(49 in.)

minimum

1000mm (39-3/8 in.)

minimum

In Canada, similar floor protection must be provided 18

inches (457mm) in front and 8 inches (203mm) from the

sides and rear of the stove. *

See exception.

*EXCEPTION: Non-combustible floor protections must

extend beneath the flue pipe when installed with horizontal

venting and extend 2 inches (51mm) beyond each side.

See Figure 11.4.

USA required

Canada recommended

Figure 11.3

4

Installation

Figure 11.1

Figure 11.2

Figure 11.4

WARNING

Fire Risk.

• Hearth pads must be installed exactly as

specified.

High temperatures or hot embers may ignite

concealed combustibles.

NOTE:

Illustrations and photos reflect typical installations and are FOR DESIGN PURPOSES ONLY.

I

llustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design preference

Hearth & Home Technologies reserves the right to alter its products.

USA

USA

CANADA

Advertising