D. fan wiring with remote, E. control module operation – Quadra-Fire QF130 User Manual

Page 27

Advertising
background image

27

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

PLUG

120V EXISTING

OUTLET

GRN (2)

BLK (2)

BLK (2)

GRN (2)

BLK (2)

STEPS

3 & 4

WHT (2)

BLOWER

SPEED CONTROL

(RHEOSTAT)

SENSOR SWITCH

STEPS

1 & 2

STEP 5

BLOWERS

BLOWER

RECEPTICLE

BLK
GRN

BLK

BLK
GRN

BLK

WHT

GRN

BLK

BLK

GRN

WHT

BLK

BLK

PLUG INTO 120V

EXISTING OUTLET

DC REGULATOR

RECEPTICLE

AUX 300 MODULE

FAN

TO CONTROL

MODULE

D. Fan Wiring with Remote

This appliance may be used with an RC200 or RC300

remote control. See Figure 10.3.
1. Remove cord assembly spades from rheostat and

sensor switch.

NOTICE: Fan speed and operation are controlled by the

remote control. The sensor switch and rheostat are no

longer needed.

2. Plug two cord assembly spade connectors together.
3. Unplug fan cord assembly from standard cord assembly.
4. Plug fan cord assembly into AUX300 module.
5. Plug AUX300 module into the standard cord assembly.

NOTE: USE ZIP TIES TO RESTRAIN

THE LOOSE WIRES UNDERNEATH

THE APPLIANCE AND KEEP THEM

AWAY FROM THE BLOWER WHEEL

(FAN BLADES).

NOTE: IF ANY OF THE ORIGINAL

WIRE AS SUPPLIED WITH THE

APPLIANCE MUST BE REPLACED,

IT MUST BE REPLACED WITH TYPE

105

0

C RATED WIRE.

E. Control Module Operation

See Section 2.H for control module operation instructions.

Figure 10.3 Wiring Diagram - Fan with RC200/RC300 Remote

NOTE: SENSOR SWITCH AND

RHEOSTAT SPEED CONTROL MUST

BE REMOVED FROM CIRCUIT IF

SYSTEM IS CONTROLLED WITH

RC200/RC300 REMOTE.