FlexPhones Master Installation and Operation Manual

INSTALLATION

DIM jumper configuration

Removing either or both of the Dim jumpers mutes the program audio dur-

ing a talkback session, while inserting either or both will dim the program audio
approximately 20db below normal program levels. Use the table below along with
the jumper layout sheet in the appendix to properly configure. Factory defaults have
these jumpers installed.

Right ear talkback enable jumper:

In a talkback session, talkback audio is always feed into the left ear. Placing

a jumper over the desired header will enable talkback audio in the right ear. Use the
table below along with the jumper layout sheet in the appendix to properly config-
ure. Factory default has these jumpers installed.
Function

Chnl 1 Chnl 2 Chnl 3 Chnl 4 Chnl 5 Chnl 6

LT Dim

JP5

JP8

JP11

JP14

JP17

JP20

RT Dim

JP6

JP9

JP12

JP15

JP18

JP21

RT T/B Enable JP7

JP10

JP13

JP16

JP19

JP22

Auxiliary Remote/Local jumper set-up

We provide the wire attached to pin 5 of each RJ45 for use by the

user. The wire terminates on a three-position header. The header is labeled JPxx.
The factory default is set to Remote. Use the table below along with the jumper lay-
out sheet in the appendix to properly configure.
Function

RMT 1 RMT 2 RMT 3 RMT 4 RMT 5 RMT 6
JP24

JP26

JP28

JP30

JP32

JP34

Remote

1 & 2

1 & 2

1 & 2

1 & 2

1 & 2

1 & 2

Local

2 & 3

2 & 3

2 & 3

2 & 3

2 & 3

2 & 3

Remote Control input jumper set-up

Each optically isolated input is equipped with a four-position header.

The header is labeled JPxx. The factory default is set for a DRY (5 vdc source) input
(switch, contact, open collector) with a jumper between 1 & 2 and another jumper
over 3 & 4. To change the input to WET (user supplied voltage between 5 and
24vdc), remove both jumpers and place ONE jumper over pins 2 & 3. Use the table
below along with the jumper layout sheet in the appendix to properly configure.
! NOTE: Refer to the schematic diagram for the proper polarity when attaching
equipment to each input.

Function

RMT 1 RMT 2 RMT 3 RMT 4 RMT 5 RMT 6 All-Call
JP23

JP25

JP27

JP29

JP31

JP33

JP35

Wet

A = Anode A = Anode A = Anode A = Anode A = Anode A = Anode A = Anode

2 & 3

B = Cath

B = Cath

B = Cath

B = Cath

B = Cath

B = Cath

B = Cath

Dry

A = Gnd

A = Gnd

A = Gnd

A = Gnd

A = Gnd

A = Gnd

A = Gnd

1 & 2 / 3 & 4

B = Cath

B = Cath

B = Cath

B = Cath

B = Cath

B = Cath

B = Cath