13

IN

12V OUT

AUDIO ADJ.

PHANTOM

MIC

LINE

ON

NC

VIDEO

VOL

RS485

CONTACT

LINE

IN

OUT

MIC IN

CONTACT

CONTACT

IN

OUT

RS485

1

2 C 1

2 C

+

RS-232C

24V

OUT

1

2

AUDIO

DE

UT

VIDEO OUT

Monitor

Network
Video Receiver

N-VR2010

VIDEO IN

Connect the 24 V AC or 24 V DC
when not using a PoE-compatible hub.

Note: Connect the 12 V DC terminal when using a remote controller.

Remote Controller
C-RM500

RS-485(+)

RS-485(-)

DC12 V

RS-485

Rear

8.7. Serial Port

[RS-232C]
Use a null modem cable such as the YR-S2320 when connecting control terminals of the remote controller to
this terminal. No RS-232C connector plug is supplied with the unit.

[RS-485]
Connect the control terminal of the remote controller to this terminal.

• Applicable cable

Solid cable:

AWG28 (Ø 0.32 mm) - AWG22 (Ø 0.65 mm)

Stranded cable:

AWG28 (0.08 mm

2

) - AWG22 (0.32 mm

2

)

Note

Strip the cable sheath approximately 10mm, then insert the cable while pushing down on the terminal button
with a screwdriver.

• RS-232C Connector D-sub 9P

1 2 3 4 5

6 7 8 9

1

2

3

4

5

6

7

8

9

Unconnected

RXD (Reception data)

TXD (Transmission data)

Unconnected

GND

Unconnected

RTS (Transmission request)

CTS (Transmission permission)

Unconnected

Both the RTS and CTS pins are internally shorted.