CHAPTER 8 ISOLATED ANALOG PROGRAMMING OPTION

8.1 INTRODUCTION

Isolated Analog Programming is an internal Option Card for analog programming of the Gene-
sys

TM

power supply series. The option is factory installed and cannot be obtained with a GPIB

(IEEE-488) Interface. Output Voltage and Output Current can be programmed and readback
through optically isolated signals which are isolated from all other ground references in the power
supply.

There are two types of Isolated Analog programming cards:

1. 0-5V/0-10V option (PN: IS510): Using 0-5V or 0-10V signals for programming and read-

back.

2. 4-20mA option (PN: IS420): Using current signals for programming and readback.

8.2 SPECIFICATIONS

8.2.1 0-5V/0-10V OPTION (PN: IS510)

Output Voltage programming accuracy

%

+/-1

Output Current programming accuracy

%

+/-1

Output Voltage programming temperature coefficient

PPM/°C

+/-100

Output Current programming temperature coefficient

PPM/°C

+/-100

Input impedance

Ohm

1M

Absolute maximum voltage

Vdc

0-15

Programming
Inputs

Max. voltage between program inputs and supply outputs

Vdc

600

Output Voltage monitoring accuracy

%

+/-1.5

Output Current monitoring accuracy

%

+/-1.5

Output Impedance (see Note)

Ohm

100

Monitoring
Outputs

Max. voltage between monitoring outputs and supply
outputs

Vdc

600

NOTE:
Use 100Kohm minimum input impedance for the monitoring circuits to minimize the readback
error.

8.2.2 4-20mA option (PN: IS420)

Output Voltage programming accuracy

%

+/-1

Output Current programming accuracy

%

+/-1

Output Voltage programming temperature coefficient

PPM/°C

+/-200

Output Current programming temperature coefficient

PPM/°C

+/-200

Input impedance

Ohm

50

Absolute maximum input current

Vdc

0-30

Programming
Inputs

Max. voltage between program inputs and supply outputs

Vdc

600

Output Voltage monitoring accuracy

%

+/-1.5

Output Current monitoring accuracy

%

+/-1.5

Maximum load impedance

Ohm

500

Monitoring
Outputs

Max. voltage between monitoring outputs and supply
outputs

Vdc

600