REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993

-4-

TABLE RM-A

PPTC MODIFIED WIRING FOR EXTERNAL MODEM TO TTY CONNECTION

FIGURE 4
REMOTE MAINTENANCE USING IMDU MODEM (DK16 ONLY)

REMOTE
MODEM

RS-232
CABLE

CO LINE

TELEPHONE

NETWORK

ROM

AND

RAM

DK16
CO LINE
CIRCUIT

DK16

CO line connects to IMDU port (619)
via: DISA, Ring transfer, or ringing
assignments in Program 78

PIOU OR PIOUS

CO LINE

IMDU

TIME
SWITCH

PPTC1A-5M ADAPTOR

QSMU OR PIOU/PIOUS,
TTY JACK
MODULAR PIN NO.

MODULAR PIN NO.

1

2

3

4

5

6

RD

TD

DSR

DTR

DCD

SG

RD,

TD,

DSR,

DTR,

DCD,

SG,

6

5

4

3

2

1

to

to

to

to

to

to

3*

2*

6

20*

8*

7

4 Jumper to 5

RD

TD

DSR

DTR

DCD

SG

RTS to CTS

to

to

to

to

to

to

DB25 PIN NO.

MODEM
RS-232
LEAD NAME

PPCT (Modular to DB25) ADAPTOR, MODIFIED WIRING FOR
CONNECTING TTY JACK TO AN EXTERNAL MODEM:

IMPORTANT:

*

PPTC1A-5M, pins 2 & 3 and pins 8 & 20 must

be reversed in the field, as shown, for modem
connection. Set Hayes modem to track status of
carrier detect signal (AT & C1) and to answer
(ATS0 = 1).