Caution – Trion HE Plus 2000 User Manual

Page 11

Advertising
background image

INSTALLATION

CAUTION:

Only a trained, experienced servicer should install this Electronic Air Cleaner. The Front
Panel Assembly, Power Tray Assembly, Ionizing-Collecting Cells and Pre-filters should be
removed before installation. To remove the Power Tray Assembly, remove the two (2)
screws from inside the top front of the cabinet. Keep this hardware for re-installation of
the Power Tray Assembly after the air cleaner installation is completed and before
operation. A thorough check-out of the unit installation should be completed before
operation of the air cleaner.

INSTALLER HELP LINE

If you have any questions on installation issues or problems, please call

Technical Support 866-829-2440

Prior to installing this Electronic Air Cleaner:

1. Read instructions carefully for safe operation. Failure to follow instructions can

damage the product or cause a hazardous condition and may result in physical
harm.

2. Check the ratings stated on the product data label to make sure it is suitable for

your application.

3. Select a location for the air cleaner.

4. Remove the old furnace filter and discard.

5. The air cleaner cannot remove existing dirt from the blower and ducts. Clean the

area thoroughly before you begin installation.

6. Remove unit’s Front Panel Assembly and slide the Pre-filters and Ionizing-

Collecting Cells out of the cabinet. Remove the Power Tray Assembly and place
ALL components safely aside. Also, remove and discard cardboard shipping
inserts from inside Front Panel Assembly and bottom of cabinet.

PHYSICAL INSTALLATION OF THE AIR CLEANER

This Electronic Air Cleaner can be installed in any position, except with the Front Panel
Assembly facing UP or DOWN. The section TYPICAL MOUNTING POSITIONS illustrates
examples of proper air cleaner mounting with a variety of furnace installations.

Installation

16

SYMPTOM

Rapid Arcing or
Zapping

Excessive Ozone
Smell

Radio or Television
Interference

Hissing or Sizzling
Noise

Green LED Light is
not On

Red LED Light is
not On

POSSIBLE CAUSES

Broken or loose ionizing wire (s)

Dirty Ionizing-Collecting Cell

Damaged or bent collector plates

Dirty insulator caps on Ionizing-
Collecting Cell

Defective Air Flow Sensor

Loose high voltage connections

Poor electrical ground

Poor electrical contact in the secondary
electrical circuit

No power available

Loose wiring at ON/OFF switch

Defective ON/OFF switch

ON/OFF switch not in ON position

Loose wiring within power pack
assembly

Broken or shorted electrical
component

Excessive dirt build-up on ionizing
wires

Contact board assemblies are corroded
or carbonized

Broken ionizing wire

Dirty Ionizing-Collecting Cell

Foreign object located between
collector plates

Damaged or bent collector plates

Insulators are corroded or carbonized

CORRECTIVE ACTION

Remove broken or loose wire and replace
with new wire

Clean the Ionizing-Collecting Cell

Straighten plates with needle nose pliers
or replace entire Ionizing-Collecting Cell

Clean with warm soapy water and rinse
well

Clean or replace Air Flow Sensor

Rewire Air Cleaner to the HVAC system
blower by qualified HVAC contractor

Uncommon occurrence- check for good
common ground for air cleaner

Ensure that there is a good connection
between the top of the Ionizing-Collecting
Cell and the bottom of the contact board

Contact HVAC contractor

Reset circuit breaker
Replace fuse

Check for secure connection

Replace ON/OFF switch

Turn the unit ON

Check for secure connections
Contact HVAC contractor

Contact HVAC contractor

Clean wires with alcohol and allow to dry
thoroughly before turning the unit ON

Replace contact board assembly

Remove broken wire and replace with new wire

Clean the Ionizing-Collecting Cell

Remove object from Ionizing–Collecting Cell

Straighten plates with needle nose pliers
or replace entire Ionizing-Collecting Cell

Replace insulators or Ionizing-Collecting Cell

Troubleshooting