Fusing

This warmer draws 4.0 amps at 120 Volts. Be sure the circuit to which it will be connected is adequately
wired and fused to accept this added load.

SECTION VI

A. Preventive Maintenance

Observe well for lime build-up. Remove as necessary. Lime will affect the performance of your unit.

B. Purpose of each electrical component.

ON/OFF Switch - Turn on power to device. Signal light glows to show power is on.

Operating Thermostat - (Thermo Disc Type for 1529), (Infinite Switch for 1523 and 1527)
Cycles heating unit on and off to maintain an average temperature of 170 (filled with water
level mark in well.)

Heating Unit - Offers heat to bottom of well.

Hi-Temperature Thermostat - (bi-metal type) turns buzzer on when water boils. (1529 Models).

Audible Buzzer - Signals operator to fill well with water immediately.(1529 Models).

TROUBLE SHOOTING INFORMATION

DURING NORMAL OPERATION (WATER IN WELL)

Symptom

1. No Signal Light

No Heat
No Buzzer

2. No Signal Light

Heats

3. Signal Light Glows

No Heat

4. Signal Light Glows

Buzzer Sounds

Symptom

1. Signal Light Glows

No Buzzer

Possible Cause

No incoming power.
Switch Defective.
Wire off.

Switch light defective.

Wire off.
Heating unit defective.
Operating thermostat defective.

Hi-temperature thermostat defective.

Possible Cause

Buzzer defective.
Hi-Temperature thermostat defective.

ABNORMAL OPERATION (NO WATER IN WELL - EVAPORATED DRY)