VOLUME: The volume buttons will operate the

volume function on any remote control amplifier that

accepts RC5 commands. They are provided solely

for your convenience, as there are no volume control

functions on the CD player

H

IDDEN

M

ODES

These are only accessible with the use of an RC5

handset with the appropriate keys (Not the supplied

handset).

SHUFFLE: Press SHUFFLE followed by PLAY to

listen to tracks in a random order. To cancel Shuffle

mode, press SHUFFLE again.

INTRO: Press INTRO and the player will scan

through the disc playing the first 10 seconds of each

track. Press INTRO while in Play mode and the

player will scan through the disc playing the first 20

seconds of each track. To cancel either Intro mode

simply press PLAY.

T

IMER

M

ODE

Your player is equipped with a Timer Mode. This

allows the player to automatically play a disc when

powered on from the mains via the use of an exter-

nal timer. It is switched off by default at the factory.

To turn this on follow the instructions below using

Diagram 2 (see page 8).

Before attempting to re-configure your player, dis-

connect the mains lead at the wall socket. Having

made your player safe, remove the cover by un-

screwing the screws located on the top and those

on the underside using a combination of a T10

security torx driver and a No.1 posi-drive screwdriver

lift the cover and locate the yellow jumper located in

the bottom right corner of the main PCB using

Diagram 2 (page 8). To set the Timer ON remove the

yellow jumper or place it in such a way that it is held

by only one pin. Replace the cover and re-connect

the mains lead to the wall socket. The Timer Mode

should now be operational via the use of an external

mains power timer.

Talk Electronics’ policy of continued research and development means that the above specification may change without
notice.
The Thunder has been manufactured to conform with the protection requirements of the EC Council directive 89/336/EEC
relating to EMC by application of the following standards:

EN50081-1 1992 Emissions Standard
EN50082-1 1992 Immunity Standard

and also the requirements of the EC low voltage directive relating to electrical safety by application of the following standard

BSEN60065: 1994 Safety standard

For the purposes of testing the Thunder was used with the mains cables and high quality interconnects supplied by Merlin
Cables. Compliance with the above standards can only be made if the unit is installed as per this manual and using the
correct cables.

*Guarantee: 3 Years return to dealer.

To help us provide you with the most efficient service please return your guarantee card promptly. Your CD player is
guaranteed against manufacturing and component defects for a period of 3 years. The guarantee does not cover and
damage caused by accident, misuse, neglect or through incorrect installation, adjustment or repair by unauthorised
personnel or the cost of collecting the Thunder from you and returning it to the dealer. The above does not effect your
statutory rights as a consumer.

E & OE. Due to our policy of continued development we reserve the right to change the specifications at any time.

*Upon return of Guarantee Card

S

PECIFICATIONS

T

HUNDER

2.2

Maximum Output Voltage

2.6V* RMS

Output Impedance

<100 ohms

Frequency Response

5 – 20k

±

0.2dB

Distortion 1kHz max output

<=0.001%

Signal - to - Noise Awtd

–104dB

Mains Voltage

230V /115V/100V AC

±

10%

Dimensions

width

440mm

height

89mm

depth

325mm

(allow at least 400mm for connections)

Weight per unit

unpacked

11.4kg

packed

13.2kg