Electrical connections

Before connecting the appliance, check that the vol-

tage quoted on the rating plate - that is, the nominal vol-

tage of the appliance - corresponds to the available

mains voltage. The rating plate can be found on the

lower housing of the ceramic glass hob.

The mains connection must be carried out by an expert

electrician. The VDE-regulations and the valid pre-

scriptions by the local power suppy boards have to be

compiled with.

Prior to connection it should be checked whether the

voltage stated on the type plate -- i.e. the nominal vol-

tage of the appliance and of the oven/control box -- is

identical with the prevailing mains voltage. The type

plate ist located on the hobs bottom.

The heating element voltage amounts to 230 V ~. The

appliance will also perfectly perform with the former

mains voltage of 220 V ~.

The mains connection must be carried out in a way that

an all--pole insulating device is existing with a contact

opening of at least 3 mm, e.g. LS--automatism, earth--

leakage circuit--breaker or fuse.

A wire of type H05VV-F or of higher rating is to be used

as supply cable.

The mains terminal is located in the bottom of the

appliance behind a covering slide. It can be opened

with a screw driver (pict.).

According to existing mains voltage the appliance has

to be connected in correspondence with the diagrams

of connecting possibilities. The bridges of the terminal

board are to be changed accordingly, if need be.

The protective conductor is to be connected to terminal

. The protective conductor must be longer than live

leads.

The cable connections have to be established as

prescribed and the terminal screws be firmly tigh-

tened.

Afterwards the supply cable has to be secured by strain

relief device and the covering slide must be closed by

firmly pressing down (until it enganges).

Prior to first use remove any possibly existing labels

and protective film from the ceramic glass plate or the

frame of the hob.

After connecting the electrical supply, all cooking

zones should be briefly switched on one after the

other at their maximum power, in order to test

whether they are operational.

strain relief device

Mains terminal

in the bottom of the hob

L1

N

5

Connecting possibilities

1

2

3

4

L1

L2

N

5

1

2

3

4

L1 L2 L3

N

5

1

2

3

4

L1

L2

5

1

2

3

4

L1

L2

L3

5

1

2

3

4

(L3)

1 L + N

2 L + N

3 L + N

2 L

3 L

230 V ~

400 V 2 N ~

400 V 3 N ~

230 V 2 ~

230 V 3 ~

changing brid-

ges of the ter-

minal

3 x 6 mm

2

(30 A)

4 x 2,5 mm

2

(20 A)

3 x 4 mm

2

(32 A)

5 x 2,5 mm

2

(16 A)

4 x 2,5 mm

2

(20 A)

Advertising