Comparing function “ “ “ “comp comp comp comp – Toshiba PWU001Z-1 User Manual

Page 10

Advertising
background image

E6580724

4.3. Comparing function “

 “

 “

 “comp

comp

comp

comp

””

This function enables the operator to compare data stored in two memories that are selected from
among four memories of the parameter writer's memories A, B and C and the inverter's memory as well
as to search a parameter which is different in the setting value from others.
The comparing function cannot be used for editing data because it is provided for searching parameters
which are different in setting values from others.

Use the “Remote keypad” function described in Section 4.6 to edit data.

Operating procedure

Key

LED indication

Key operation and description

chc

init

c0py

When the parameter writer is turned on as it is connected with the inverter,

“chc” appears on the display first and then “init” appears to indicate that

the power supply is being initialized. Lastly, the display shows “copy”.

c0py

c0mp

Selecting a desired function

Select to “comp” (comparing function) with the SFT key.

Each time the SFT key is pressed, indication on the display changes from

"copy' to “comp” (comparing function). "prot " (memory protecting

function), “clr” (memory initializing function) and to "copy" again in this

order.

c0mp

in

Entering the selected function

After selecting "comp" with the SFT key, press the ENT key and "in"

(selecting inverter memory) appears on the display.

in

a

b

c

in

Selecting a memory to compare its data with another

Each time the SFT key is pressed, indication on the display changes from

''in” (selecting inverter memory) to "a'' (selecting memory A), “b”' (Selecting

memory B), “c” (selecting memory C) and to “in" again in this order.

Select the copy destination area.

in

in

a

Entering the memory to compare its data with another

After selecting ''in '' (selecting inverter memory, for example) with the SFT

key, press the ENT key and ”in

a

" appears on the display.

in

a

in

b

in

c

in

a

( a

in

a

b

a

c

a

in

)

Selecting a memory to compare its data with that of the previously selected

memory

Each time the SFT key is pressed, indication on the display changes from “in

a

" (comparing data between inverter memory and memory A) to “in

b

(comparing data between inverter memory and memory B),”in

c

(comparing data between inverter memory to memory C), and to “in

a

again in this order.

If the memory A is selected as the memory storing the original data, indications

differently appear as shown in parentheses.

in

a

Entering the selected memory to compare its data with the original

After selecting “in

a

” (selecting memory A to compare its data with that of

the inverter's memory for example) with the SFT key, press the ENT key and

the parameter writer starts comparing data of the two memories with each

other.

f000

f002

(If no parameter different

from the other is
searched,
the display shows

end

)

Executing comparing data (searching different parameters)

After confirming that “f000” is appearing on the display, execute comparison

of data in order of communication number (refer to the Table of communication

numbers.). When the parameter writer searches a parameter different from the

other, it discontinues comparing operation and shows the parameter's

communication number in blinking numerals.

Press the ENT again to continue the comparing operation.

end

Comparing is complete

With completion of data comparison, “end” appears on the display first and

then “_ _” of a check data (check sum of the original data) appears. Value of

the check data changes depending on the condition of the original data.

comp

Ending comparing

Press the ENT key and indication on the display returns to “comp”.

If the ESC key is pressed, the parameter writer returns to the status one before.

SFT

SFT

ENT

ENT

SFT

ENT

ENT

ENT

Advertising