Toro WIRED RAINSENSOR 53853 User Manual

Page 2

Advertising
background image

Installation Procedure
v

Adjust Rain Sensitivity:

The sensitivity setting determines the amount of

rainfall required to trigger the RainSensor and suspend automatic watering.

The RainSensor is factory-set at 6mm. Prior to installing the RainSensor, adjust

the rainfall sensitivity as preferred to one of four optional settings as indicated in

Figure 2

.

To adjust, turn the cap slightly to disengage the pins

from the current setting. Adjust the cap up or down to

the preferred slot position, then re-engage the pins.
Note:

Make sure the slot is correctly aligned with the pin

when making an adjustment. Do not force the cap into

position.
Note:

The 3mm setting is not recommended for loca-

tions where high-humidity is common.
v

Set Sensor Operation Mode (Applies to Model 53769, RainSensor Only):

The RainSensor is preset for normally-closed sensor operation, but can be

easily converted to normally-open if needed. Prior to installation, determine

whether your automatic timer requires a normally-closed or normally-open sen-

sor by referring to the timer user’s guide. If a normally-open sensor is required

(for example, when used with a Toro ECx

TM

or GreenKeeper

®

timer), configure

the RainSensor as shown in Figure 3.

Model 53853 only:

If using the Freeze version, model 53853, and your

controller requires Normally Open Sensor operation, the sensor connection can

not be used. Instead, refer to the wiring configuration B and C under “Connect

RainSensor Wiring

” section.

1. Using a small screwdriver, release and

remove the access cover by depressing

the two retaining tabs. Slide the control

board assembly out of the housing.

See Figure 3.

2. Carefully remove the wire connector from

the left pin of the microswitch and attach it

to the center pin. Leave the right wire

connected.

3. Slide the control board back into the

housing making sure it is properly aligned.

Install the access cover with the connection

wire knot on the inside the housing.

6mm

13mm

25mm

19mm

3mm

Figure 2

Normally Open

Normally Closed

Figure 3

Advertising
This manual is related to the following products: