1.TROUBLESHOOTING FOR THE HARDWARE

Refilling With Staples 55

1 TROUBLESHOOTING FOR THE HARDWARE

6

Close the front cover of the Finisher.

If the message “Check staple cartridge” remains, repeat the procedure above from steps 1 to 6.

„

Refilling the Saddle Stitch unit staples

When the staples of the stapler in the Saddle Stitch Finisher MJ-1104 have run out, refill the staples following the
procedure below.

5

Fit the staple cartridge into the stapler.

When fitting the staple cartridge, hold the green-labeled portion of the
bracket securely so that the bracket will not move.
Insert the cartridge until it is caught by the latch and fixed with a click.

1

Open the front cover of the Finisher, and pull out the
Saddle Stitch unit until it stops.

2

Remove the staple cartridges.

Replace both cartridges at a time.

3

Press the buttons on both sides of the cartridge.

The transparent cover of the cartridge is lifted.

2

1

2

1