An A/V 80Hz high pass filter switch provides instant conversion to 5.1 and higher order systems where a separate subwoofer
below 80Hz is required. Filter characteristics are according to the international standards for this setup. This response is also
shown diagramatically in Figure 1.

Listening to well recorded male or female spoken word or vocals at the normal listening position is a good way to check and
optimise the available settings. Difficult environments and variable listening distances produce varying degrees of boost from
the flat position in the 50Hz to 800Hz area. Graphical representations of the responses available by setting the switches are
shown below. The linear or flat response positions for the DIP switches are always clearly shown in the diagrams below and
also on the rear panel of the speaker.

The Tannoy ActivAssist

™ software package is available to help with the DIP switch settings. Using a standard laptop with the

microphone and cables supplied in the pack, the performance of the speaker in a particular environment can be assessed and
a recommended set of switches set up.

Fig. 1. Full range of equalisation and trim available.

Fig. 2. Range of adjustment available and settings for the first 4 DIP switches. All other DIPs set to 'Flat'

Diagramatic View of EQ Dip Switches: LF EQ + Av Filter

20 way DIP Switch Bank (4+4+2+4+6)

10Hz

100Hz

1Khz

10kHz

-10dB

+10dB

0dB re 2.8v

@ 1 metre

500Hz

5kHz

200Hz

2kHz

20kHz

20Hz

50Hz

LF EQ

Low Mids

Hz

Up

Highs

1 1 1 0

1 1 1 0

0 0

0 0 0 0

0 0 0 0 0 0

1 1 1 1

1 1 1 0

0 0

0 0 0 0

0 0 0 0 0 0

1 1 0 0

1 1 1 0

0 0

0 0 0 0

0 0 0 0 0 0

0 0 0 0

1 1 1 0

0 0

0 0 0 0

0 0 0 0 0 0

1 0 0 0

1 1 1 0

0 0

0 0 0 0

0 0 0 0 0 0

80Hz AV Filter (AV on/off)

Mids

3.1: ANALOG INPUT

XLR:

2= +ve (hot), 3= -ve (cold), 1= screen, shield or signal ground.

3 way Jack:

tip=+ve (hot), ring= -ve (cold), sleeve= screen, shield or signal ground.

For unbalanced XLR connection short pin 1 to pin 3 and use 2= +ve (hot), 3= -ve (ground).
For unbalanced 3 way Jack short ring to sleeve and use tip= +ve (hot), sleeve= -ve (ground).

3.2: DIGITAL SPDIF INPUT

The input impedance is the SPDIF specification at 75 ohms and the 24 bit DAC supports 44.1, 48 and 96kHz sampling rates.
Please use a high quality* SPDIF coaxial phono (RCA) cable to connect the source equipment (eg CD player, DAT/ADAT or PC
sound card) to one of the speakers. Connect a second (phono to phono) high quality cable from this speaker to the second
speaker of the stereo pair. Select whether each speaker converts left channel or right channel audio as appropriate using the
switch adjacent to the SPDIF input connector. For true mono requirements set the switch to mono. If volume can be controlled
from the source equipment, set the source equipment volume level to minimum and the speaker volume control to maximum
(fully clockwise). If volume cannot be controlled by the source equipment (eg a simple CD or DAT etc) set the volume control
on the speaker to minimum (fully anticlockwise) to prevent excessive sound levels. The volume control adjusts the analogue
level after the DA converters to preserve the full digital dynamic range.

* In order to comply fully with EMC regulations, the SPDIF input and SPDIF thru should be connected using metal-shelled
connectors and good quality shielded cable suitable for digital audio.

3.3: CONNECTING YOUR SPEAKERS

Having chosen an appropriate location for your monitors and arranged them accordingly, connect the power cord to the mains
socket and turn the power on. The LED on the front panel will now glow red. Push the Tannoy logo on the front panel to operate
the switch to bring the amplifier out of standby mode and into operational mode. Set the volume control on the rear panel to
zero (fully anticlockwise). Connect the audio signal source (console output) to the input connector (combined XLR/jack socket)
or SPDIF at the back of the monitor.

3.4: USER CONTROLS

A/V (80Hz): a switch to the bottom left of the bank of DIP switches sets the system high pass filter to either flat or –6dB at 80Hz.
The 80Hz setting is used when the speakers are in combination with a subwoofer for low frequency effects such as Dolby Digital,
AC3, DTS etc playback situations. For all other situations set this switch to flat. This response can be seen in Figure 1 above.

Left/Right/Mono: a switch at the bottom left of the bank of DIP switches sets the SPDIF DAC to sense the left, right or combined
stereo information (mono) from the digital stream. Set the left hand speaker to ‘Left’ and the right hand speaker to ‘Right’ for
2 channel stereo, or to ‘mono’ for single speaker monitoring.

Analogue/Digital: a switch adjacent to the XLR/Jack combi socket selects whether the speaker is receiving a signal from the
balanced/unbalanced analogue input combi socket, or, from the SPDIF phono (RCA) digital input. Both may be connected
simultaneously but only one can be selected at any one time.

4.0: EQUALISATION POSSIBILITIES

Note: In the diagrams which follow, the corner frequency shown as 50Hz will vary according to the specification relating to
the particular model which has been chosen. Please refer to the detailed specification section at the end of this manual for more
details. Smaller models will have a slightly higher corner frequency and larger models will have a lower corner frequency. The
diagrams have been prepared to make the visualisation of the EQ possibilities easier to understand. The transitions of the
speaker amplitude response bewteen frequency bands will be gradual and not as sharp as the diagrams show. Note the +10dB
and -10dB calibrations on the charts. EQ settings should never be at opposite extremes eg -8dB low mid contour with -2dB
mids and +3dB highs.

There are 4 basic frequency bands that can be adjusted. The range of adjustment is purposely restricted so that although effective
in the majority of environments, it is difficult to set the speaker to have a totally unacceptable response. A 'flat' setting means
flat within specification as measured in an anechoic chamber, on axis, under free field conditions in the far field (3 metres away).
The frequency bands are:

Bass Corner Frequency: The 'Q' value of the bass unit and cabinet volume alignment can be altered giving +3dB, flat, -
1.5, -3, and -4.5 dB relative to the -3dB point shown in the specification. This provides a degree of boost and cut in the 45Hz
to 65Hz area. Figure 2 shows the range of adjustment available together with the DIP switch settings for the first 4 DIP switches.
All other DIP switches are shown in the anechoic flat positions.

+3dB

+1.5dB

Large

Medium Normal

+1.5dB

+2dB

+0.75dB

+1dB

0dB

Flat

Flat

Flat

Flat

-2dB

-0.75dB

-1dB

-1dB

-4dB

-1.5dB

-2dB

-6dB

-3dB

-2dB

-8dB

-3dB

( AV 80Hz HiPass on slide switch)