Installation, Installation -- continued, Autocross jumpers – Transition Networks E-100BTX-FX-05 User Manual

Page 3: Continued installing the fiber cable, Installing the copper cable

Advertising
background image

4

E-100BTX-FX-05

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

Installation -- Continued

AutoCross Jumpers

The AutoCross feature allows either straight-through (MDI) or crossover
(MDI-X) cables to be used when connecting to devices such as hubs,
transceivers, or network interface cards (NICs). AutoCross determines the
characteristics of the cable connection and automatically configures the unit

to link up, regardless of the cable configuration.

High-temperature board, J3, 3-Pin header settings:
1. Orient the board as shown in the photo.
2. Position the jumper as illustrated below.

SW1

(4-Position)

AutoCross 3-Pin Header

set to Enabled

J3 AutoCross 3-Pin
Header

J3

Enable AutoCross

J3

Disable AutoCross

High Temperature Device

Standard board, J1, 3-Pin header settings:
1. Orient the board as shown in the photo.
2. Position the jumper as illustrated below.

J1

J1

J1 AutoCross 3-Pin Header

AC = AutoCross

Enabled

AC = AutoCross

Disabled

[email protected] -- Click the “Transition Now” link for a live Web chat.

5

Installation

-- Continued

Installing the fiber cable

1.

Locate a 100Base-FX compliant fiber cable with male, two-stranded TX to
RX connectors installed at both ends.

2.

Connect the fiber cables to the media converter as described:

Connect the male TX cable connector to the female TX port.

Connect the male RX cable connector to the female RX port.

3.

Connect the fiber cables to the other device (another media converter, hub,
etc.)
as described:

Connect the male TX cable connector to the female RX port.

Connect the male RX cable connector to the female TX port.

Installing the copper cable

1.

Locate or build 100Base-TX compliant copper cables with male, RJ-45
connectors installed at both ends.

2.

Connect the RJ-45 connector at one end of the cable to the RJ-45 port on
the media converter.

3.

Connect the RJ-45 connector at the other end of the cable to the RJ-45 port
on the other device (switch, workstation, etc.).

Connect fiber cable
to media converter
as shown.

Connect fiber cable

to other device

(media converter,

hub, etc.) as shown

RX

TX

RX

TX

RJ-45 port

on the other device

(switch, work station, etc.)

RJ-45 port

on the media

converter

Advertising