Electrical Connections

WARNING:THIS APPLIANCE MUST BE EARTHED.

The manufacturer declines any liability should this
safety measure not be observed.

If the plug that is fitted to your appliance is not suitable
for your socket outlet, it must be cut off, and the
appropriate plug fitted.

Remove the fuse from the cut off plug. The cut off
plug should then be disposed of to prevent the hazard
of electric shocks, in case it should be plugged into a
13 Amp socket in another part of your home.

IMPORTANT

The wires in the mains
lead are coloured in
accordance with the fol-
lowing code:

Green and Yellow - Earth

Blue - Neutral

Brown - Live

If you fit your own plug,

the colours of the wires in the mains lead of your
appliance may not correspond with the markings iden-
tifying the terminals in your plug.
To fit the plug, proceed as follows:

Connect the green and yellow (earth) wire to the ter-
minal in the plug which is marked with the letter «E»
or the earth symbol , or coloured green and yellow.

Connect the blue (neutral) wire to the terminal in the
plug which is marked with the letter «N» or coloured
black.

Connect the brown (live) wire to the terminal in the
plug which is marked with the letter «L» or coloured
red.

The plug moulded on to the lead incorporates a fuse.
For replacement, use a 13 Amp BS1362 fuse. Only
ASTA or BSI approved fuses should be used.

The plug must not be used if the fuse cover/carrier is
lost. The cover/carrier is indicated by the coloured
insert at the base of the plug.

A replacement cover/carrier must be obtained from
your local Tricity Bendix Service Centre.

There is a list of these at the end of this instruction
book.

Avoid connecting the tumble dryer to the same socket
as your washing machine (or any other appliance) by
means of an adaptor. Have an extra socket installed if
necessary, by a qualified electrician.

Note

Installation, and, in particular, connection to the elec-
tric mains and to the discharge vent must be carried
out by a competent person or qualified electricians.

Please ensure that when the appliance is installed it is
easily accessible for the engineer, in the event of a
breakdown.

GREEN & YELLOW

13 AMP FUSE

BROWN

CORD CLAMP

BLUE

13

AMP

P0329