Installation – Transition Networks E-MCC-1600 User Manual

Page 2

Advertising
background image

INSTALLATION

WARNING: Do NOT connect Power Supply Module to AC power
before installing in Media Conversion Center. Failure to observe this
caution could result in equipment damage and/or personal injury or
death.
CAUTION: Wear a grounding device and observe electrostatic
discharge precautions when setting Master/Slave configuration switch
and when installing Power Supply Module in Media Conversion
Center. Failure to observe this caution could result in damage to, and
subsequent failure of, Power Supply Module.

Set Master/Slave Switch, if Applicable

1.

Determine if Master/Slave switch is installed on Power
Supply Module.

NOTE: If Master/Slave switch is installed on ANY Power
Supply Module installed in chassis, ensure that AT LEAST
ONE
Power Supply Module in the E-MCC-1600 chassis
is configured as the primary (master) Power Supply
Module.

2.

Set Master/Slave switch, if necessary.

To configure the Power Supply Module as the primary
(master) Power Supply Module, set Master/Slave switch
to position labeled “MASTER”.

To configure the Power Supply Module as the secondary
(slave) Power Supply Module, set Master/Slave switch to
position labeled “SLAVE”.

Install Power Supply Module in Chassis

1.

Locate Power Supply Module installation slot on Media
Conversion Center chassis back.

2.

Remove Power Supply Module protective plate from
installation slot by removing and retaining two (2) screws
that secure protective plate to back of Media Conversion
Center chassis.

3.

Carefully slide Power Supply Module into Media
Conversion Center installation slot, aligning Power
Supply Module with installation guides.

NOTE: Ensure that the Power Supply Module is firmly
seated against the chassis backplane.

4.

Carefully install two (2) screws (retained in Step 2)
through Power Supply Module into Media Conversion
Center, rotating clockwise to secure.

Connect to Power

1.

Connect female end of power cord to power receptacle
on Power Supply Module.

2.

Plug male end of power cord into correct voltage AC
rack or wall socket.

3.

Set Power Supply Module power switch to “I”.

4.

Verify that Media Conversion Center is powered by
observing illuminated Power LED and fan operation.

I

0

MASTER

SLAVE

MASTER

SLAVE

I

0

Advertising