Tripp Lite Isolator Series UL60601-1 User Manual

Model #: is500hg

Advertising
background image

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail:

[email protected]

Model #: IS500HG

Isolation Transformer - Medical Grade line noise reduction and spike suppression

Highlights

Complete line isolation, noise filtering and surge suppression; ideal for

sensitive equipment

500 watts, 4 outlets, 10-ft. power cord

Hospital-grade plug and receptacles

Leakage current less than 100 micoramps

Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule

purchases

Description

Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode
surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1
medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive
electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels
less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground
reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility
switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Active transformer filtering
provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to
harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS500HG
includes 4 widely spaced NEMA 5-15R hospital-grade output receptacles, a 10-ft. power cord, hospital-grade input plug, circuit breaker overload
protection, and lighted power switch. Rugged all-metal unit ships ready for placement in any industrial, medical, office or network environment.
PLUG/OUTLETS: Input - NEMA 5-15P Hospital Grade; Output - 4 NEMA 5-15R Hospital Grade ELECTRICAL: 120V AC, 60Hz, 2.1A (Requires
NEMA 5-15R wall receptacle)

Package Includes

IS500HG Isolation Transformer

Instruction manual with warranty information

Features

The IS500HG Medical Grade Isolation Transformer offers line isolation and continuous noise filtering

Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line

Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for

the protection of sensitive electronic equipment in patient-care areas.

Reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps.

Secondary neutral-to-ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment

Serves as an inexpensive alternative to dedicated circuits and site electrical upgrades

Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops

Active transformer filtering offers continuous common-mode noise rejection with no wearable parts; unique ability to reduce surges in the

worst of power environments to harmless levels

Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode

Includes 4 widely spaced NEMA 5-15R hospital-grade output receptacles, a 10-ft. power cord, hospital-grade input plug, circuit breaker

overload protection and lighted power switch.

Rugged all-metal unit housing; ships ready for upright tower placement in any industrial, medical, office or network environment

Specifications

Advertising