TECHNICAL SPECIFICATIONS

PHySICAL
Size

42 x 483 x 233mm (1U x 19” x 9.2”)

Weight

2.6Kg

Housing

19” rackmounted steel enclosure

Colour

Beige

Power

- Voltage

Mains power adapter 100-240Vac

(supplied)

Output voltage 12Vdc @ 2.0A

- Current
Consumption

300mA

- Backup Battery

Internal Lithium Ion battery giving a

minimum of three hours backup time.

Power fail reported to system internally.

Environmental

- Temperature

-10º to 50ºC (14º to 122ºF)

- Humidity

95% non condensing

LED Indicators

Online/Offline, Ethernet connection,

Activity/Status, Power and Heartbeat

FUNCTIONALITy

Inputs

Two Fire Zone Inputs

Dedicated Tamper Input

Two general purpose monitored inputs

Outputs

Four volt-free changeover relays

Reader Capacity

Up to 4 optically isolated RS485

multidrop reader networks controlling

up to 16 master readers each.

The combined maximum permissible

cable run is 1.2km per port.

Controller Memory

10MB of RAM

28KB Boot Loader ROM

Database memory

Compact Flash Disk, 64MB

Storage of approximately 10,000

cards per controller, 500 with images.

Configuration/

Embedded Web Server allows full access

Management

and all administration through a

standard web browser.

Browser

Microsoft Internet Explorer 6 SP1

or higher

COmmUNICATION INTERFACE

To Card Readers

Connected to webEntry II controller

using RJ45 connectors

To System Host

Ethernet 10/100 Base T

Others

Local RS232 serial port for controller

diagnostics/ configuration and

control of external equipment.

CONNECTION OPTIONS

CEM Systems Ltd Unit 4 Ravenhill Business Park Ravenhill Road Belfast BT6 8AW Northern Ireland

Tel: +44 (0)28 9045 6767 Fax: +44 (0)28 9045 4535 email: [email protected]

www.cemsys.com

Onboard Database

The webEntry II Controller supports its own database of up
to 10,000 card records. The records include card numbers,
access level and time zone details. The database allows the
controller to validate card requests from readers.

Rack mounted Enclosure

The webEntry II Controller comes mounted in a sturdy 19-
inch 1U rack-mounted enclosure providing easy integration
into existing server locations. The webEntry II Controller
can also be wall mounted with adjustment of the supplied
brackets.

Power Failure Capability

The webEntry II Controller has its own internal UPS, giving a
minimum of three hours normal usage in the event of mains

power failure, thus keeping potential downtime to
a minimum.

System Expansion

The webEntry II Controller can readily be upgraded to form
part of a fully scaleable AC2000 access control solution for
medium and large sites. All existing wiring and readers can
remain in place eliminating the need for new hardware.

Reader Networks

The reader networks connect to four RS485 serial ports on
the webEntry II Controller, using CAT 5 cabling. Each port
is distributed over four individual RJ45 cable connections
providing ease of installation and reducing the time
required to identify a faulty reader (see connection option
diagram below).

PRODUCT HIgHLIgHTS

CEM/B/016 Rev B

Product specifications and availability is subject to change without notice. Certain product names mentioned herein may be trade names
and/or registered trademarks of their companies.

Star

(up to 4 devices

per port)

Daisy Chain

(up to 16 devices

per port)

Combination

(up to 16 devices

per port)

Exit