Symbols, Component values, Assembly numbers – Tektronix WFM 300A User Manual

Page 175: Grid coordinates, Wfm 300a, Example: id control, (id control), or /id control

Advertising
background image

9–1

WFM 300A

Section 9
Diagrams/Circuit Board Illustrations

Symbols

Graphic symbols and class designation letters are based on ANSI Standard Y32.21975.

Logic symbology is based on ANSI Y32.14–1973 in terms of positive logic. Logic
symbols depict the logic function performed and may differ from the manufacturer’s data.

Overline, parenthesis, or leading slash indicate a low asserting state.

Example: ID CONTROL, (ID CONTROL), or /ID CONTROL.

Abbreviations are based on ANSI Y1.1–1972.

Other ANSI standards that are used in the preparation of diagrams by Tektronix, Inc. are:

Y14.15, 1966 -- Drafting Practices.
Y14.2, 1973 -- Line Conventions and Lettering.
Y10.5, 1968 -- Letter Symbols for Quantities Used in Electrical Science and
Electrical Engineering.

American National Standard Institute
1430 Broadway, New York, New York 10018

Component Values

Electrical components shown on the diagrams are in the following units unless noted
otherwise:

Capacitors: Values one or greater are in picofarads (pF).

Values less than one are in microfarads (

mF).

Resistors = Ohms (

W).

The following information and special symbols may appear in this manual.

Assembly Numbers

Each assembly in the instrument is assigned an assembly number (e.g., A20). The
assembly number appears on the diagram (in circuit board outline), circuit board illustra-
tion title, and lookup table for the schematic diagram.

The Replaceable Electrical Parts List is arranged by assembly number in numerical
sequence; the components are listed by component number. Example:

Chassis–mounted components
have no Assembly No. prefix.
See end of Replaceable Electrical
Parts List

Assembly

Number

Component Number

A23 A2 R1234

Subassembly

Number (if used)

Schematic Circuit
Number

Grid Coordinates

The schematic diagram and circuit board component location illustration have grids. A
lookup table with the grid coordinates is provided for ease of locating the component.
Only the components illustrated on the facing diagram are listed in the lookup table.

When more than one schematic diagram is used to illustrate the circuitry on a circuit
board, the circuit board illustration will only appear opposite the first diagram; the lookup
table will list the diagram number of other diagrams that the other circuitry appears on.

WIRE STRAP

MODULE

PLUG

P1

NEGATIVE

PORTS

IC TYPE

CHANGED

PART

+12V

DECOUPLED OR

FILTERED VOLTAGE

R500

20K

+12V3

REAR

PANEL

INPUT

BNC

J1

(FEMALE)

PAD

FRONT PANEL

NOMENCLATURE

C1

10UF

2
3

6

7

4

U1

741

-12V

R5

1.0

NC

ROTATE

H

HEAT SINK

2

REFER TO

WAVEFORM

1 2 3

J1

R4

20K

Q8

W4

0 OHM

+11.8V

+15V

-11.8V

TP1

/VIDEO

(VIDEO)

R55

100.0

CLOCKWISE

AJUSTMENT

1

2

J3

12

W751

A3

ANALOG

BOARD

SCHEMATIC &

BOARD REF

PART NAME,

2

R100

R85

SEL

SEE PARTS LIST

FOR SELECTION

CRITERIA

SQUARE PIN

CONNECTOR

PART OF A1 MAIN BOARD

R56

100.0

Q6

-15V

SEE PARTS LIST FOR

EARLIER VALUES AND

SERIAL NUMBER RANGES.

C27

0.1UF

SCREWDRIVER

ADJUSTMENT

CIRCUIT BOARD

OUTLINE

& SNUBBER

BASE DRIVE

TITLE

FUNCTION BLOCK

INSTRUMENT NAME

SCHEMATIC NAME & NUMBER

ASSEMBLY NUMBER

VERTICAL INPUT

1

A1

COMPONENT LOCATOR GRID