ZELMER 829 User Manual

Page 58

Advertising
background image

61

3 Insert the dry fi ltration module with the SAFBAG (25)

dust bag to the container.

Prepare the vacuum cleaner for operation according

to section B.

4 The vacuum cleaner starts up with default setting of the

highest power range. One diode will light on the power level

indicator (6). Set the desired power value (this function is

only available in vacuum cleaners type 829.0) by pressing

the power adjustment buttons , (5).

ATTENTION! It is strictly prohibited to vacuum without

the dust bag and the inlet fi lter or with a damaged

dust bag. It may cause a failure of the vacuum cleaner

motor.

SAFBAG dust bag disassembly/assembly

Remove the dry fi ltration module with the SAFBAG

(25)

dust bag from the container.

ATTENTION! The water fi lter module/the dry fi ltration

module with the SAFBAG dust bag may only be

removed and inserted when the end of the hose is

removed from the vacuum cleaner opening.

1 Pull the SAFBAG dust bag interlock fastening and pull

the interlock aside.

2 Pull the fastening which attaches the SAFBAG dust bag

to the basket to release the dust bag plate.

3 Remove the dust bag.
4 Insert the SAFBAG dust bag according to the arrow

printed on the bag so that the lower part of the bag plate is in

the slot of the housing. Press the upper part of the bag plate

to the fastening until you hear a characteristic click and close

the SAFBAG dust bag interlock.

Insert the dry fi ltration module with the SAFBAG

(25)

dust bag to the container.

VACUUM CLEANING WITH THE USE OF THE
WATER FILTER MODULE

1 Press the “PRESS” button and remove the tank lid.
2 Insert the partition to the grooves in the container so that

the shutters are directed downwards. Make sure the partition

is correctly mounted in the container i.e. the partition fi ns

should cover the protrusion in the container.

3 Fill the container with 1,2 liter of water. The water level

should be in the range marked on the tank wall.

ATTENTION! Do not operate the appliance with an

empty container while vacuum cleaning with the use

of the water fi lter module.

4 Insert the fi ltration unit to the tank, make sure that the two

air stub pipes are in the openings of the vacuum cleaner body.

Prepare the vacuum cleaner for operation according

to section B.

The vacuum cleaner starts up with default setting of the

highest power range. One diode will light on the power level

indicator (6). Set the desired power value (this function is

only available in vacuum cleaners type 829.0) by pressing

the power adjustment buttons , (5).

ATTENTION! Do not operate the appliance for too

long without replacing the water in the container.

In case of long-term or very intensive vacuuming

of large amounts of dirt, the water in the tank which

constitutes the fi rst fi ltration level may in whole or in

a considerable part be absorbed by the dirt. In such

a case, exchange the water and continue vacuuming.

Avoid vacuuming surfaces covered with substances which

may favor an excessive foaming of the water inside the

tank. If you notice that the water is heavily foamed, add

a foam neutralizer recommended by the manufacturer of

the appliance e.g. “G 478 Entschäumer D” in the amount

indicated on the packaging. It can be purchased in stores

which offer ZELMER S.A. products or by mail order.

ATTENTION! Vacuuming with the amount of water in

the tank which exceeds the marked, permissible level

may cause the water to spill to the outside of the

appliance. If this situation repeats often, it may lead to

a fast clogging of the outlet HEPA fi lter.

ATTENTION! The vacuum cleaner is equipped with

a fl oat which will automatically block the suction if the

foam fi lter II (9) is heavily dirty or the liquid exceeds the

maximum level. In such a case switch off the vacuum

cleaner by pressing the on/off button (1), unplug the

appliance, clean the fi lter and empty the container.

PICKING UP WATER
If you want to use the vacuum cleaner to vacuum liquid, the

vacuum cleaner should be prepared as in the case of vacuum

cleaning with the use of the water fi lter module except that:

1 The container should be empty (without water).
2 You should use the nozzle for picking up water (21).

ATTENTION! Do not operate the vacuum cleaner with

a full container! Do not vacuum large amounts of liquid

at a time (e.g. with the hose immersed into water).

If the water exceeds the maximum level during vacuuming,

the fl oat will automatically block the suction. The maximum

capacity of the container is about 4,0 l. In such a case proceed

in the manner described above in the part concerning the

blocking of suction caused by a dirty foam fi lter.

End of operation cleaning and maintenance

Switch off the vacuum cleaner by pressing the on/off

button (1) and unplug the appliance.
Wind the cord by pressing the cord rewind button

(4). While

doing this hold the cord to make sure it is not tangled and

the plug does not hit the vacuum cleaner housing.
Press the interlock on the hose end and remove the hose

from the opening.

E