Cable specifications – Transition Networks ARCNET AR-CF-02(SM) User Manual

Page 2

Advertising
background image

Installation NOTES

Install Coax Copper

STAR TOPOLOGY

MAXIMUM coax segment to active hub is 600 meters (2000

feet) on RG-62 cable; minimum does not apply.

BUS TOPOLOGY

Devices attached to coax bus must be located AT LEAST six

(6) feet apart.

MAXIMUM coax bus length is 300 meters (1000 feet);

minimum is 1.8 meters (6 feet).

Device(s) attached to EACH END of bus must be terminated.

NOTE: If the media converter is installed at one end of the

bus, use the configuration switch to terminate the media

converter.

CONFIGURATION SWITCH

NOTE: Set configuration switch (located on the side of media converter)
according to site installation requirements:

Switch 1

NOT USED

Switch 2

UP = OFF

Media converter TRANSFERS signal

DOWN = ON

Media converter TERMINATES signal.

Install Fiber

Connect one end of first fiber cable to AR-CF-02 media

converter TX connector.

Connect other end of that fiber cable to second AR-CF-02

media converter RX connector.

Connect one end of second fiber cable to AR-CF-02 media

converter RX connector.

Connect other end of that fiber cable to AR-CF-02 media

converter TX connector.

Power

Locate correct power supply adapter for site installation.

Connect media converter power connector at end of power
supply adapter cord to AR-CF-02 media converter power
receptacle.

Connect 2-prong or 3-prong external power connector on
other end of power supply adapter cord to external AC power.

CABLE SPECIFICATIONS

The physical characteristics of the cable must meet or exceed the following:

FIBER CABLE

MULTIMODE
Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Fiber Optic Transmitter Power:

min: -19.0

dBm

max: -14.0

dBm

Fiber Optic Receiver Sensitivity:

min: -32.5

dBm

max: -14.0

dBm

Wavelength:

850nM

Bit error rate:

10

-9

Maximum Cable Distance:

2 kilometers

SINGLEMODE
Fiber Optic Cable Recommended:

9 µm singlemode fiber

Fiber Optic Transmitter Power:

min: -27.0

dBm

max: -17.0

dBm

Fiber Optic Receiver Sensitivity:

min: -32.5

dBm

max: -13.0

dBm

Wavelength:

1300nM

Bit error rate:

10

-9

Maximum Cable Distance:

8 kilometers

COAX CABLE/STAR TOPOLOGY

RG-62 Cable

Cable Characteristics:

Cable type:

Coaxial RG-62/u

Impedance: 75

@ 10 MHz

Mutual Capacitance:

13 pF/ft ±20% @ 10 MHz

Maximum Attenuation:

5.5 dB/1000 feet

Maximum Cable Distance:

600 meters (2000 feet)

Minimum Distance/Connection:

0 meters (0 feet)

RG-59 Cable

Cable Characteristics:

Cable type:

Coaxial RG-59/u

Impedance: 93

@ 10 MHz

Mutual Capacitance:

13 pF/ft ±20% @ 10 MHz

Maximum Attenuation:

7.0 dB/1000 feet

Maximum Cable Distance:

450 meters (1500 feet)

Minimum Distance/Connection:

0 meters (0 feet)

COAX CABLE/BUS TOPOLOGY

RG-62 Cable

Cable Characteristics:

Cable type:

Coaxial RG-62/u

Impedance: 93

@ 10 MHz

Mutual Capacitance:

13 pF/ft ±20% @ 10 MHz

Maximum Attenuation:

5.5 dB/1000 feet

Maximum Cable Distance:

300 meters (1000 feet)

Minimum Distance/Connection:

1.8 meters (6 feet)