2. Locate the two mounting holes for the handle

assembly on the Mini-Guardian HEPA System cabinet.
They are located in close proximity to the top of the
cabinet near the corners. A lock nut should be visible
through each of the mounting holes and is held in
place by a retainer plate secured to the cabinet shell.
Verify lock nut is visible in each mounting hole.

3. Place a socket head cap screw (M0 x 35mm)

into each of the holes in the handle end brackets.
Position the handle assembly up against the Phoenix
Mini-Guardian HEPA System cabinet so as to align the
cap screws with the mounting holes in the cabinet.

It may be necessary to tilt the handle assembly
up at a slight angle in order to align the screws
with the lock nuts. Use the 8mm hex key to press
the cap screws into the mounting holes and engage
the threads of the lock nuts.

4. Tighten each of cap screws using the 8mm hex key

until the handle assembly is secured against the
cabinet surface and all space between parts is
eliminated.

2.2 Transporting the Phoenix

The Phoenix Mini-Guardian HEPA System should be upright
when transported by vehicle. It may be tipped on to its
back for loading and moving by hand or for use on location.

2.3 Location

Note the following precautions when locating the Phoenix
Mini-Guardian HEPA System:

· It is designed to be used INDOORS ONLY.
· If used in a wet area, plug it into a GROUND FAULT
INTERRUPTER.
· DO NOT use the Phoenix Mini-Guardian HEPA System as

a bench or table.

· The air inlet on top & the side outlets should be at

least  foot from walls and other obstructions to

airflow.

2.4 Electrical Requirements

The Phoenix Mini-Guardian HEPA System can be plugged
into a grounded 5 Amp circuit. It draws about 2 Amps
with clean filters and no ducting. The amp draw will
decrease slightly with added ducting and as the filters load
with particulate.
If an extension cord is required, it must have a minimum of
8 gauge conductors if 25 feet long or less and 6 gauge
conductors if greater than 25 feet long.