Nomenclature and functions, Front, Rear – TOA Electronics C-IF500 User Manual

Page 4

Advertising
background image

4

1. Power indicator [POWER]

Lights when the power is supplied.

2. Transfer rate setting switch [MODE]

Sets the transfer rate of the data to be transmitted
via the unit.

3. Data transmission indicator [TX]

Lights when data is transmitted from the Slave
terminal.

4. Data reception indicator [RX]

Lights when data is received from the Slave
terminal.

5. AC adapter input terminal *

Connect the AC adapter to this terminal.

6. 12 V DC power input terminal *

Please connect with the power supply other than
the AC adapter by the cable that attached the
supplied clamp filter.

(Please attach a clamp filter to the nearest
possible position of this controller.)

7. Ground Terminal [GND]

Please be sure to ground.

8. Master connection terminal [MASTER]

Connects to the C-RM500 Remote Controller to
split the control data transmitted from the C-
RM500.

9. Terminating resistance switch [TERMINATION]

Set this switch to ON when connecting the C-
RM500. However, there is a case that the switch
is used in the OFF position depending on the
connection method.
Refer to p. 6 for details.

10. RS-232C terminal [SLAVE/RS-232C]

Converts the data received at the Master
Connection Terminal into the RS-232C signal
level and sends out the converted signal. The
RS-232C Terminal also converts an input signal
to the RS-232C terminal into the RS-485 control
signal, and outputs the converted signal from the
Master Connection Terminal.

11. Slave connection terminal [SLAVE/A – D]

Splits an input signal to the Master Connection
Terminal into 4 and sends out the split signals.

Caution
Up to 31 C-CC501, C-CC504, C-CC551, or C-
CC554 Combination Camera can be connected to
each Slave Terminal A-D.

4. NOMENCLATURE AND FUNCTIONS

[Front]

INTERFACE UNIT C-IF500

MODE

ON

1 2 3 4

TX

RX

POWER

1

2

3

4

[Rear]

GND

MASTER

SLAVE

DC IN 12V

DC IN

12V

IN

OUT

RS-232C

GND GND

GND

A

GND

B

GND

C

GND

D

GND

OFF

TERMINATION

ON

5

6 7

8

9

10

11

Transfer Rate

1

2

3

4

38400 bps

ON

ON

ON

ON

19200 bps

OFF

ON

ON

ON

9600 bps

ON

OFF

ON

ON

4800 bps

OFF

OFF

ON

ON

2turn

power supply

12V
IN GND

clamp filter

+

-

+

* Connect the DC power supply of 12 V/over 100 mA, which suited CE standard to either input terminal.

Advertising