Connector and Test Point Descriptions

www.ti.com

4

Connector and Test Point Descriptions

4.1

Enable Jumpers/Switches –SW1 and SW2

The TPS53125EVM-599 board includes independent enable switches for each of the two outputs. When
the switch is in the DIS position, the channel is disabled and discharged per the TPS53125’s internal
discharge characteristics.

To enable VOUT1, place SW1 in the EN position. To enable VOUT2, place SW2 in the EN position.

4.2

Test Point Descriptions

Table 2

lists the test points, their labels, uses, and where additional information is located.

Table 2. Test Point Description

Test Point

Label

Use

Section

TP1

TEST1

Monitor Channel 1 Soft-Start Voltage

4.2.4

TP2

TEST2

Monitor Channel 2 Soft-Start Voltage

4.2.4

TP3

GND

Ground for Input Voltage

4.2.1

TP4

GND

Ground for Channel 1 Output Voltage

4.2.2

TP5

SW1

Monitor Switching Node for Channel 1

4.2.5

TP6

GND

Ground for Channel 2 Output Voltage

4.2.3

TP7

VO2

Monitor Output Voltage for Channel 2

4.2.3

TP8

VO1

Monitor Output Voltage for Channel 1

4.2.2

TP9

VIN

Monitor Input Voltage

4.2.1

TP10

VREG5

Monitor Output of VREG5 Regulator

4.2.6

TP11

SW2

Monitor Switching Node for Channel 2

4.2.5

CN1

VOUT1

Monitor Output Voltage for Channel 1

4.2.2

CN2

VOUT2

Monitor Output Voltage for Channel 2

4.2.3

4.2.1

Input Voltage Monitoring – TPS and TP9

The TPS53125EVM-599 provides two test points for measuring the voltage applied to the module. This
allows the user to measure the actual module voltage without losses from input cables and connectors.
Measure all input voltage measurements between TP9 and TP3. To use TP9 and TP3, connect a
voltmeter positive terminal to TP9 and negative terminal to TP3.

4.2.2

Channel 1 Output Voltage Monitoring – TP4 and TP8 or CN1

TPS53125EVM-599 provides two test points for measuring the voltage generated at the VO1 Output by
the module. This allows the user to measure the actual output voltage without losses from output cables
and connectors. Measure all DC Output voltage between TP8 and TP4. To use TP8 and TP4, connect a
voltmeter positive terminal to TP8 and negative terminal to TP4.

TPS53125EVM-599 also provides a shielded oscilloscope jack to allow ac measurements of the output
ripple. Insert an oscilloscope probe with exposed ground barrel into CN1 for all Output 1 ripple
measurements.

4.2.3

Channel 2 Output Voltage Monitoring – TP6 and TP7 or CN2

TPS53125EVM-599 provides two test points for measuring the voltage generated at the VO1 Output by
the module. This allows the user to measure the actual output voltage without losses from output cables
and connectors. Measure all dc output voltage measurements between TP7 and TP6. To use TP7 and
TP6, connect a voltmeter positive terminal to TP7 and negative terminal to TP6.

TPS53125EVM-599 also provides a shielded oscilloscope jack to allow ac measurements of the output
ripple. Insert an oscilloscope probe with exposed ground barrel into CN2. for all Output 2 ripple
measurements.