Configuration Options

2-4

2.6

Configuration Options

There are a number of options available via shorting jumpers. These are
detailed below:

Table 2−3.

Jumper Settings

Reference

Designator

Description

Factory Set

Condition

Position

Optional Position

Designator

1−2

2−3

W1

Single supply operation

Not installed

W2

Select negative supply for op amp

−Vs

AGND (0 V)

W3

Select positive supply for op amp

+Vs

+Vcc (5 V)

W4

Select signal source for channel 0

Signal is via op amp

Signal is directly from P1.2

W5

Select positive voltage reference

Onboard reference

Reference via P1.18

W6

Select digital power

5 V

3.3 V

W7

Select negative voltage reference

Onboard reference

Reference via P1.20

W8

CSTART, initiate manual conversion

Disabled

Enabled

W9

FS mode

Disabled

Enabled

W10

Device always selected

Disabled

Enabled