Section 4.8 – Texas Instruments TMS320TCI6486 User Manual

Page 83

Advertising
background image

www.ti.com

MDIO Registers

4.8

MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW)

The MDIO user command complete interrupt (unmasked) register (USERINTRAW) is shown in

Figure 35

and described in

Table 28

.

Figure 35. MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW)

31

16

Reserved

R-0

15

2

1

0

Reserved

USERINTRAW

R-0

R/WC-0

LEGEND: R = Read only; R/WC = Read/Write 1 to clear; -n = value after reset

Table 28. MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW) Field

Descriptions

Bit

Field

Value

Description

31-2

Reserved

0

Reserved

1-0

USERINTRAW

MDIO User command complete event bits. When asserted, a bit indicates that the previously
scheduled PHY read or write command using that particular USERACCESS register has
completed. Writing a 1 will clear the event and writing 0 has no effect.

83

SPRUEF8F – March 2006 – Revised November 2010

C6472/TCI6486 EMAC/MDIO

Submit Documentation Feedback

Copyright © 2006–2010, Texas Instruments Incorporated

Advertising