Pressure control repair – Sherwin-Williams ULTIMATE 824-032 User Manual

Page 18

Advertising
background image

18

824-033

Pressure Control Repair

7202B

Fig 16

213

202

214

201

23

230

23a

229

214

216

217

213

215

218

219

220

1

Torque to 150 in. lbs (17 N–m)

1

C

A

B

2.

Carefully slide new o–ring (220) down bore (A) of
motor control (201) into o–ring groove (B). Make
sure o–ring is in groove around its entire circumfer-
ence.

NOTE: O–ring (220) is made of

PTFE

which is more

difficult to work with.

3.

Carefully slide new transducer and plastic
spacer (217) down bore. Loosely attach
bracket (218), screws (213), and washers (214).

4.

Seat transducer into o–ring by drawing down
screws and washers until bracket is flush with
motor control surface.

5.

Carefully remove transducer and verify that o–ring
is seated correctly and not pushed out of groove. If
not seated correctly use new o–ring and repeat
steps 2 through 5.

6.

When o–ring is correctly installed, reinstall trans-
ducer and tighten screws to 150 in. lbs (17 N–m).
Install spacer (216) and C–clip (215). Re–connect
electrical lead and re–assemble sprayer.

7.

Follow Operation Startup procedures for sprayer
on page 7 using compatible fluid.

8.

Inspect weep hole (C) for any leakage.

9.

If any leakage is present, replace o–ring repeating
steps 1 through 9.

Advertising