Generator maintenanc, Engine maintenanc, Generator maintenance engine maintenance – Troy-Bilt M F 8 5 CT 30331 User Manual

Page 17: Warning

Advertising
background image

15

4. Remove oil drain plug and drain oil completely into a

suitable container.

5. Reinstall oil drain plug and tighten securely. Remove oil

fill cap.

6. Slowly pour oil (about 20 oz.) into oil fill opening (B) to

the point of overflowing (C) at oil fill cap. DO NOT
overfill.

7. Reinstall oil fill cap. Finger tighten cap securely.

8. Wipe up any spilled oil.

Service Air Cleaner

Your engine will not run properly and may be damaged if
you run it with a dirty air cleaner.

Replace the air cleaner every 25 hours of operation or once
each year, whichever comes first. Replace more often if
operating under dirty or dusty conditions.

To service the air cleaner, follow these steps:

1. Loosen screws (A) and remove air cleaner cover (B).

2. Carefully remove cartridge (C) from base (D).

3. Install clean (or new) air cleaner assembly inside cover.

Dispose of old filter properly.

4. Assemble air cleaner cover onto base and tighten

screws.

Service Spark Plug

Change the spark plug every 100 hours of operation or once
each year, whichever comes first. This will help your engine
to start easier and run better.

1. Clean area around spark plug.

2. Remove and inspect spark plug.

3. Check electrode gap with wire feeler gauge and reset

spark plug gap to recommended gap if necessary (see
Specifications).

4. Replace spark plug if electrodes are pitted, burned or

porcelain is cracked. Use the recommended
replacement spark plug. See Specifications.

5. Install spark plug and tighten firmly.

Service Spark Arrester

The engine exhaust muffler has a spark arrester screen.
Inspect and clean the screen every 100 hours of operation or
once each year, whichever comes first.

If you use your generator on any forest-covered, brush-
covered, or grass-covered unimproved land, it must have a
spark arrester. The spark arrester must be maintained in
good condition by the owner/operator.

A

B

C

D

WARNING

Contact with muffler area can result in serious
burns.

Exhaust heat / gases can ignite combustibles,
structures or damage fuel tank causing a fire.

• DO NOT touch hot parts and AVOID hot exhaust gases.

• Allow equipment to cool before touching.

• Keep at least 5 feet (1.5 m) of clearance on all sides of

generator including overhead.

• Code of Federal Regulation (CFR) Title 36 Parks, Forests, and

Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.

Advertising