Battery Replacement

The thermometer operates on one CR2032 lithium battery (as
installed
). If readings grow dim or irregular, the battery may need
to be replaced. To replace the battery:
1. Gently pull off the silicone backing under the base of the

thermometer head.

2. Loosen the screw located inside one of the holes in the

base/stem part of the thermometer (The screw will not come
all the way out).

3. Gently pull the base/stem part of the thermometer from the

thermometer head. Do not pull forcefully, as the wires inside
the thermometer may detach.

4. Remove the screw that secures the battery cover. Gently

remove the battery cover. (Take care not to misplace the screw.)

5. Replace the old battery with the new battery, with the “+” sign

showing.

6. Replace the battery cover (the 2 tabs opposite the screw hole

should tuck under the black plastic casing). Replace the battery
cover screw.

7. Gently push the thermometer head and base back together

until the pieces click securely in place.

8. Replace the screw in the hole under the base of the

thermometer.

9. Replace the silicone backing. The thermometer is ready for use.

Specifications

Temperature Range: 16º to 302ºF or -9º to 150ºC

Resolution: 0.1ºF or ºC full range

Timer: 9 minute 59 second countdown

7 Preprogrammed Tea Types: White, Green, Oolong, Black,
Herbal, Puerh, Darjeeling

Battery: CR2032 (included)

Auto Shut-Off: After 10 minutes of nonuse

Response Time: 1 second