Multiply-by-n clock option, Timing requirements (see figure 12), See figure 10 and figure 12) – Texas Instruments TMS320VC5402 User Manual

Page 38

Advertising
background image

TMS320VC5402

FIXEDĆPOINT DIGITAL SIGNAL PROCESSOR

SPRS079E – OCTOBER 1998 – REVISED AUGUST 2000

38

POST OFFICE BOX 1443

HOUSTON, TEXAS 77251–1443

multiply-by-N clock option

The frequency of the reference clock provided at the X2/CLKIN pin can be multiplied by a factor of N to generate
the internal machine cycle. The selection of the clock mode and the value of N is described in the clock generator
section.

When an external clock source is used, the external frequency injected must conform to specifications listed
in the timing requirements table.

NOTE:

All revisions of the ’5402 can be operated with an external clock source, provided that the proper

voltage levels be driven on the X2/CLKIN pin. It should be noted that the X2/CLKIN pin is referenced to
the device 1.8V power supply (CVdd), rather than the 3V I/O supply (DVdd). Refer to the recommended
operating conditions section of this document for the allowable voltage levels of the X2/CLKIN pin.

timing requirements (see Figure 12)

MIN

MAX

UNIT

Integer PLL multiplier N (N = 1–15)

20‡

200

tc(CI)

Cycle time, X2/CLKIN

PLL multiplier N = x.5

20‡

100

ns

tc(CI)

Cycle time, X2/CLKIN

PLL multiplier N = x.25, x.75

20‡

50

ns

tf(CI)

Fall time, X2/CLKIN

8

ns

tr(CI)

Rise time, X2/CLKIN

8

ns

† N = Multiplication factor
‡ The multiplication factor and minimum X2/CLKIN cycle time should be chosen such that the resulting CLKOUT cycle time is within the specified

range (tc(CO))

switching characteristics over recommended operating conditions [H = 0.5t

c(CO)

]

(see Figure 10 and Figure 12)

PARAMETER

MIN

TYP

MAX

UNIT

tc(CO)

Cycle time, CLKOUT

10

tc(CI)/N†

ns

td(CI-CO)

Delay time, X2/CLKIN high/low to CLKOUT high/low

4

10

17

ns

tf(CO)

Fall time, CLKOUT

2

ns

tr(CO)

Rise time, CLKOUT

2

ns

tw(COL)

Pulse duration, CLKOUT low

H–2

H

ns

tw(COH)

Pulse duration, CLKOUT high

H–2

H

ns

tp

Transitory phase, PLL lock up time

30

m

s

† N = Multiplication factor

tc(CO)

tc(CI)

tw(COH)

tf(CO)

tr(CO)

tf(CI)

X2/CLKIN

CLKOUT

td(CI-CO)

tw(COL)

tr(CI)

tp

Unstable

Figure 12. External Multiply-by-One Clock Timing