Startup, Shelving installation / operation – True Manufacturing Company GDM-3 User Manual

Page 8

Advertising
background image

7

7

A. The compressor is ready to operate. Plug in the cooler.

B. The refrigerator is designed to maintain cabinet

temperatures of 38˚F to 40˚F (3.3˚C to 4.4˚C).

C. Excessive tampering with the control could lead to service

difficulties. Should it ever become necessary to replace

temperature control, be sure it is ordered from your

TRUE dealer or recommended service agent.

D. Good air flow in your TRUE unit is critical. Be careful

to load product so that it neither presses against the back

wall, nor comes within two inches of the evaporator

housing. Refrigerated air off the coil must circulate down

the back wall.

NOTE

If the cooler is disconnected or shut off, wait five minutes before

starting again.
RECOMMENDATION

Before loading product we recommend you run your TRUE unit

empty for two to three days. This allows you to be sure electrical

wiring and installation are correct and no shipping damage

has occurred. Remember, our factory warranty does not cover

product loss!
REPLACEMENT PARTS

TRUE maintains a record of the cabinet serial number for your

cooler. If at any time during the life of your cooler, a part is

needed, you may obtain this part by furnishing the model number

and serial number to the company from whom you purchased

the cooler. Call Toll-Free: (800)-424-TRUE (Direct to Parts

Department). (800)-325-6152 (U.S.A. & Canada only) or call:

(636)-240-2400.

STARTUP

INSTALLATION / OPERATION INSTRUCTIONS

............ www.truemfg.com ............

True Food Service Equipment, Inc.

SHELVING INSTALLATION /

OPERATION

SHELF INSTALLATION:
Step 1
A.
Hook shelf clips onto shelf standards.

(see illustration).

B. Position all four shelf clips equal in distance from the

floor for flat shelves.

WIRE SHELVES:
Wire shelves are oriented so that cross support bars are

facing down.

Step 2
Place shelves on shelf clips making sure all corners are

seated properly.

Shelf
Clip

Shelf

Temperature Control and light switch are located next to each other on

the interior ceiling of the cabinet behind the light and cabinet fan.

The evaporator drain pan is located inside the refrigerator and it

needs to be manually drained