Tripp Lite IS1800HG User Manual

Model #: is1800hg

Advertising
background image

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail:

[email protected]

Model #: IS1800HG

Isolation Transformer - Medical Grade line noise reduction and spike suppression

Highlights

Complete line isolation, noise filtering and surge suppression; ideal for

sensitive equipment

1800 watts, 6 outlets, 10-ft. power cord

Hospital-grade plug and receptacles

Leakage current less than 100 microamps

Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule

purchases

Description

Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode
surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1
medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive
electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels
less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground
reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility
switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Active transformer filtering
provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to
harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS1800HG
includes 6 widely spaced NEMA 5-15R hospital-grade output receptacles, a 10-ft. power cord, hospital-grade input plug, circuit breaker overload
protection, and lighted power switch. Rugged all-metal unit housing; ships ready for placement in any industrial, medical, office or network
environment. PLUG/OUTLETS: Input - NEMA 5-20P Hospital Grade; Output - 6 NEMA 5-20R Hospital Grade ELECTRICAL: 120V AC, 60Hz, 2.1A
(Requires NEMA 5-15R wall receptacle)

Package Includes

IS1800HG Isolation Transformer

NEMA5-15P replacement plug

User manual with warranty information

Features

The IS1800HG Medical Grade Isolation Transformer offers line isolation and continuous noise filtering

Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line

Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for

the protection of sensitive electronic equipment in patient-care areas.

Reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral to

ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment

Serves as an inexpensive alternative to dedicated circuits and site electrical upgrades

Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops

Active transformer filtering offers continuous common-mode noise rejection with no wearable parts; unique ability to reduce surges in the

worst of power environments to harmless levels

Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode

Includes 6 widely spaced NEMA5-20R hospital-grade output receptacles, a 10-ft. power cord, hospital-grade input plug, circuit breaker

overload protection, and lighted power switch

Ships with NEMA5-20P input plug installed, package includes NEMA5-15P user-installable hospital-grade replacement plug for compatiblity

with common 15A wall receptacles

Advertising