Appendix xii: ok-to-move circuit diagram – Thermal Dynamics (a Thermadyne Company) Merlin 3000 User Manual

Page 82

Advertising
background image

APPENDIX

78

Manual 0-2533

APPENDIX XII: OK-TO-MOVE CIRCUIT DIAGRAM

A-01081

PIERCE

DELAY

0 - 3 seconds

OFF = OK-To-Move

24 VAC Source

Merlin 3000 or Merlin 6000 or Merlin 6000GST with

Remote Control RC6010 / Standoff Control SC10

OK-To-Move Circuit

OK

Logic PCB

J2-14

J2-16

J15-11

J15-10

J42-12

J42-14

OK PS

D82

OK OUT

D37

Pierce Delay

0 - 3 Seconds

OK

Standoff Control SC11

K12

OK

+

J11-7

J11-6

E1

J8-24

J40-14

J11-5

J40-12

J8-22

J11-8

A-01082

24VAC Source

K12 Energized prior to

and during pierce delay

TB2-9

TB2-10

Merlin 3000, 6000

or 6000GST