Instructions for the installer – Tricity Bendix TBG 640 User Manual

Page 12

Advertising
background image

12

Ignition HT Spark

Spark Generator

Ispra Control's BF 50046 - 230-240V 0.6 YA T 120

Spark Gap

Fixed

OVERALL DIMENSIONS

Width:

580 mm.

Depth:

500 mm.

Height:

88 mm.

Burner

Dia. Tap By-pass

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid

40

Aeration adjustment none

Instructions for the Installer

CUT OUT DIMENSIONS

Width:

550 mm.

Depth:

470 mm.

Thickness: 30 mm.

BURNER

RAPID

SEMI-RAPID

AUXILIARY

(large)

(medium)

(small)

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

NOMINAL THERMAL
POWER kW

3.0

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW
RATE m

3

/h

0.286

0.057

0.190

0.038

0.095

0.028

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

NOMINAL THERMAL
POWER kW

2.8

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW
RATE g/h

202

43.5

144

29

72

21,5

NOZZLE REFERENCE

86

40

71

32

50

28

NATURAL GAS

20 mbar

TYPE OF

GAS

CHARACTERISTICS

LPG GAS

28-30/37 mbar

1/100 mm

1/100 mm

VALUE = 49.92 MJ/Kg

VALUE = 37.78 MJ/m

3

Ws - 50.7 MJ/ m

3

Rear Left Burner (semi rapid)
Heat Input

2.0 kW (6824 BTU/HR)

Front Left Burner (rapid)
Heat Input

3.0 kW Natural Gas (10236 BTU/HR)

2.8 kW L.P.G. (9554 BTU/HR)

SUPPLY CONNECTIONS

Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:
230-240V 50Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge
fuse.

This appliance complies with the EEC Directive No
89/336, concerning suppression of radio electrical
interference.

CLASS APPLIANCE: 3

APPLIANCE
CATEGORY: II2H3+

APPLIANCE
GAS SUPPLY: Natural gas G20 / 20mbar

Rear Right Burner (semi rapid)
Heat Input

2.0 kW (6824 BTU/HR)

Front Right Burner (auxiliary)
Heat Input

1.0 kW (3412 BTU/HR)

Advertising