Toshiba – Toshiba Adjustable Speed Drive H3 User Manual

Page 95

Advertising
background image

TOSHIBA

9 - 26

Parameter Explanations (cont'd)

Item 283,

PANEL OPERATION MODE SELECTION

- Cycle power after changing this parameter.

This parameter limits what can be done via the keypad. Panel ESTOP in remote mode is ALWAYS valid.

The values entered here that are zero or are a power of two have one function assigned to them:

0: Keypad does nothing

1: Reset drive fault only

2: Monitor only

4: ESTOP only

8: Run/Stop only

16: Read parameters only

32: Change parameters only

The rest of the possible parameter values are combinations of the above.
Note: to "change parameters only", "read parameters only" must also be selected.

TO RESET AFTER "0" HAS BEEN PROGRAMMED IN ITEM 283:
1. Press four keys simultaneously: LOCAL/REMOTE, PRG, READ/WRITE, and

up arrow

2. Drive will display

ENTER PASS NUMBER 0

3. Pass number is programmed in Item 284,

PASS NUMBER

. Enter pass number with

arrows and hit READ/WRT.

4. If entered correctly,

PASS NUMBER ENTERED CORRECTLY

will display briefly and Item

283 will be reset to a value of 63, allowing all keypad operations.

If

ENTER PASS NUMBER

doesn't appear after pressing the four keys, cycle power and try again.

Specifications

Precautions

Wiring

Jumpers

Panel

Keypad

Parameters

Programming

Service

Dimensions

Index

Inspection

Item 284,

PASS NUMBER

- Incorrect entry of the setting in this parameter prevents resetting

keypad lockout (Item 283 set to "0"). Item 284 is viewable through RS232 port.

Item 285,

CPU VERSION

- This is a read-only parameter. This manual is for the version 120 CPU. Version

120 added the following features to version 5101: input terminal functions 52,53, and 54; output terminal

functions 62 and 63; "RR" special input function #4; PID lower limit, peak voltage, peak current, and

calibration settings for AM/FM terminal functions; peak voltage and peak current monitor choices;

drooping control.

Item 286,

ROM VERSION

- This is a read-only parameter. "5120" is the default setting with a

version 120 CPU (230/460 volt drive). Application-specific option ROMs are available from Toshiba.

Item 287,

EEPROM VERSION

- This read-only parameter shows control board EEPROM version.

Item 288,

INVERTER TYPEFORM

- This read-only parameter identifies the drive model number:

Typeform

Model

Typeform Model

24

H3U2035

25

H3U2055

26 H3U2080

27

H3U2110

28 H3U2160

29

H3U2220

2A H3U2270

2B

H3U2330

45

H3U4055

46 H3U4080

47

H3U4110

48 H3U4160

49

H3U4220

4A H3U4270

4B

H3U4330

4C H3U4400

4D

H3U4500

4E H3U4600

4F

H3U4750

50 H3U410K

51

H3U412K

52 H3U415K

53

H3U420K

54 H3U425K

55

H3U430K

Advertising