TP-Link TL-SG3109 User Manual

Page 18

Advertising
background image

0



The DST can be set according to unique start and end dates for a particular year or as a recurring period for any year.
For a specific setting in a particular year, complete the fields in the Daylight Savings area; for a recurring setting, complete
the fields in the Recurring area.
Daylight Savings:

USA — The device switches to DST at 2:00 a.m. on the first Sunday of April, and reverts to standard time at 2:00 a.m.

on the last Sunday of October.

European — The device switches to DST at 1:00 am on the last Sunday in March and reverts to standard time at 1:00

am on the last Sunday in October. The European option applies to EU members, and other European countries using
the EU standard.

Other — The DST definitions are user-defined based on the device locality. If Other is selected, the From and To fields

must be defined.

Time Set Offset (1-1440) — Used for non-USA and European countries to set the amount of time for DST (in minutes).
The default time is 60 minutes.
From — Indicates the time that DST begins in countries other than the USA and Europe, in the format Day/Month/Year
in one field and HH:MM in another. For example, if DST begins on October 25, 2007 at 5:00 am, the two fields should be
set to 25/Oct/07 and 05:00. The possible field values are:

Date — The date on which DST begins. The possible field range is 1-31.
Month — The month of the year in which DST begins. The possible field range is Jan-Dec.
Year — The year in which the configured DST begins.
Time — The time at which DST begins. The field format is HH:MM. For example: 05:30.

To — Indicates the time that DST ends in countries other than the USA and Europe, in the format Day/Month/Year in
one field and HH:MM in another. For example, if DST ends on March 23, 2008 at midnight, the two fields should be 23/
Mar/08 and 00:00. The possible field values are:

Date — The date on which DST ends. The possible field range is 1-31.
Month — The month of the year in which DST ends. The possible field range is Jan-Dec.
Year— The year in which the configured DST ends.
Time — The time at which DST starts. The field format is HH:MM. For example: 05:30.

Recurring:
Recurring — Enables user-defined DST for countries in which DST is constant from year to year, other than the USA
and Europe.
From — The time that DST begins each year. In the example, DST begins locally every first Sunday in April at midnight.
The possible field values are:

Day — The day of the week from which DST begins every year. The possible field range is Sunday-Saturday.
Week — The week within the month from which DST begins every year. The possible field range is 1-5.
Month — The month of the year in which DST begins every year. The possible field range is Jan-Dec.
Time — The time at which DST begins every year. The field format is Hour:Minute. For example: 02:10.

To — The time that DST ends each year. In the example, DST ends locally every first Sunday in October at midnight.
The possible field values are:

Day — The day of the week at which DST ends every year. The possible field range is Sunday-Saturday.
Week — The week within the month at which DST ends every year. The possible field range is 1-5.
Month — The month of the year in which DST ends every year. The possible field range is Jan-Dec.
Time — The time at which DST ends every year. The field format is HH:MM. For example: 05:30.

2. Define the Date, Local Time and Time Zone Offset fields.

3. To configure the device to automatically switch to DST, select Daylight Savings and select either USA, Euro-pean, or

Other. If you select Other, you must define its From and To fields. To configure DST parameters that will recur every year,
select Recurring and define its From and To fields.

Advertising