OPERATING THE UNIT AS AN AIR COMPRESSOR (Model No. 3001 Only)

Warning:

DO NOT INFLATE TIRES OR FLIP AIR COMPRESSOR "ON/OFF" SWITCH WHILE THE UNIT
IS PLUGGED INTO 110 AC POWER SOURCE!

1. Snap air chuck on tire valve stem (some wheel covers may require use of valve stem extension).

2. Flip "ON/OFF" air switch on front panel to "ON" position.

3. Tire will inflate to preset pressure and compressor will shut off.

4. Disconnect air chuck from tire valve stem (compressor will come on again).

5. Flip "On/Off" air switch on front panel to "Off" position.

6. See Compressor section below to adjust shut off pressure.

Adjusting the Compressor Shut Off Pressure

1. Remove back panel by removing

(2) 1/4” – 20 bolts securing panel.

2. Locate the pressure switch

and set screw (center of switch).

3. When adjusting shut-off pressure,

turn no more than 1/2 turn between settings.

4. To increase pressure setting, turn

clockwise (1/4 turn = approximately 4 lb.).

5. To decrease pressure setting, turn counter-

clockwise (1/4 turn = approximately 4 lb.).

6. Check pressure setting by inflating a tire and

checking tire pressure with an air gauge.
If more adjustment is necessary, return to step 4 or 5.

7. Secure back panel with (2) 1/4” – 20 bolts bolts.

Air
Hose
Connector

Pressure
Set
Screw

Compressor

Advertising