Setting the angle between cabinets

Precise adjustment of inter-cabinet angle is achieved by selecting one of nine
possible engagement positions of the rear flyplates, giving a range of angles
between 0° and 16° in 2° increments.






Rigging an Array of up to 16 cabinets with the FB-1061 flybar

1. Select a suitable pick up point on the flying grid, and choose the inter-cabinet angles to achieve the desired

array angle.

2. Attach the external rigging or motor to the chosen pick up point on the central

spine of the flying grid, using a shackle rated at one tonne or greater. The
shackle eyes must be at least 26mm apart to fit correctly onto the spine.

3. It is suggested to pre-assemble the cabinets in modules of two or three units,

setting the pre-determined inter-cabinet angle as you go. Then attach the first
module to the flying grid, and raise the array to allow a second module to be attached underneath. Repeat for
the remaining modules, and raise the array into position using appropriate lifting equipment.

4. When attaching to static array positions the suggested method is to pre-assemble the entire array including

the flying grid, and lift it into position using appropriate lifting equipment.

Turbosound Ltd, Star Road, Partridge Green, West Sussex RH13 8RY