Before using your dishwasher for the
first time:

1. Ensure that the electrical and water connections comply

with the installation instructions

2. Remove all packaging from inside the appliance

3. Set the water softener

4. Pour 1 litre of water inside the salt container and then fill

with salt

5. Fill the rinse aid dispenser

6. Run a Rinse and Hold programme.

Setting the water softener

The dishwasher is equipped with a water softener designed to
remove minerals and salts from the water supply, which would
have a detrimental or adverse effect on the operation of the
appliance.
The higher the content of these salts, the harder your water is.
Water hardness is measured in equivalent scales, Clarke
degrees, French degrees and PPM (parts per Million).
The softener should be adjusted according to the hardness of
the water in your area. Your local Water Authority can advise
you on the hardness of the water in your area.
The dishwasher is factory set at level 3.
If this level is not suitable for your area the softener should be
adjusted.

If your water is level 1 it is already soft and therefore there
is no need to use salt.
With the setting of the water softener at level 1 the salt
indicator light on the control panel will always remain off.
Use salt from level 2 upwards.

From level 2 upwards, if salt refilling is necessary, the salt
indicator light will illuminate only in setting mode and at
the end of the washing programme.
During the run of the programme it will remain off.

Before use

4

1. MAINS ON indicator light

2. MAINS ON push button

3. Door handle

4. Programme selection push buttons

5. Indicator lights

Phase indicator lights

WASH
illuminates when the washing phase is running

DRYING
illuminates when the drying phase is running

END
illuminates when the washing programme has ended

Salt indicator light

SALT
illuminates when the salt has run out and the salt
container requires refilling.

The control panel

Level

Use of

salt

French

degrees

(°TH)

PPM

(Parts per

Million)

Clarke

degrees

1

2

3

4

5

NO

YES

YES

YES

YES

< 6

6 - 21

22 - 35

36 - 49

50 - 63

< 8

8 - 30

31 - 50

51 - 70

71 - 90

< 80

81 - 300

301 - 500

501 - 700

701 - 900

Water hardness