– 5 –

GENERAL ADJUSTMENTS

SPECIFIC INFORMATIONS

CONVERGENCE ADJUSTMENTS
NOTE: Before attempting any convergence adjustments,

the receiver should be operated for at least fifteen
minutes.

CENTER CONVERGENCE ADJUSTMENT

1. Display built-in cross-dot pattern using the TEST SIG-

NAL SELECTION function.

2. Adjust the BRIGHTNESS and CONTRAST Controls

for well defined pattern.

3. Loosen the tightening ring and adjust two tabs of the

4-Pole Magnets to change the angle between them
(See figure 4.) and superimpose red and blue vertical
lines in the center area of the picture screen.
(See figure 3.)

4. Turn the both tabs at the same time keeping the con-

stant angle to superimpose red and blue horizontal
lines at the centre of the screen. (See figure 3.)

5. Adjust two tabs of 6-Pole Magnets to superimpose red/

blue line with green one. Adjusting the angle affects
the vertical lines and rotating both magnets affects the
horizontal lines.

6. Repeat adjustments 3, 4, 5 keeping in mind red, green

and blue movement, because 4-Pole Magnets and 6-
Pole magnets interact and make dot movement com-
plex.

7. After completing the “CENTER CONVERGENCE AD-

JUSTMENT” tighten the tightening ring to fix the mag-
nets.

Figure 3.

Xv COIL ADJUSTMENT

Adjust the Xv coil (on the deflection yoke) to correct
misconvergence at both sides on screen.
Use a hexagonal tip stick (plastic) to adjust the core of
coil.

BLU

BLU RED

RED

6-POLE MAGNETS
MOVEMENT

4-POLE MAGNETS
MOVEMENT

RED/BLUE

RED/BLUE GRN

GRN

Center Convergence by Convergence Magnets

R

B

B

R

B

R

R

B

Clockwise Adjustment Counterclockwise Adjustment

Xv Cross Pattern View

SCREEN-CORNER CONVERGENCE

When the misconvergence is still evident on corners even
though the above adjustment is done, use the ferrite sheet
(Part No. 23993622) to correct misconvergence.

1. Put ferrite sheets into the space under the yoke.

Decide such position that misconvergence becomes
minimum, watching picture screen. (See figure below.)

2. Remove cover paper of ferrite sheet to stick it in the

place on the tube. Put adhesive tapes on ferrite sheets
to fix.

Figure 4.

Ferrite

Sheets

Ferrite

Sheets

For correcting misconvergence
on the position A

A

4-POLE
MAGNETS

6-POLE
MAGNETS

PURITY
MAGNETS

PURITY/CONVERGENCE
MAGNETS

ADJUST THE ANGLE
(VERTICAL LINES)

FIXED

ROTATE TWO TABS
AT THE SAME TIME
(HORIZONTAL LINES)

ADJUSTMENT OF MAGNETS

Clockwise Adjustment

Counterclockwise Adjustment

X

V

Cross Pattern View

Advertising